The 10 AMP Charger is used for maintaining the battery in a ready state and recharging the battery after use when AC power is restored. Time for recharge depends upon the amount of power consumed by the pumping cycle during the AC power interruption. The pump may go back to the ready run position in a very short period of time. A completely drained battery may require up to 24 hours for full recharge. If after 24 hours of charging the battery has not reached 6 volts, the alarm will sound and not reset until the battery is brought up to a voltage of 6.5-7.0 volts.
Zoeller Charger Control Assembly Features and Benefits
LED status indicators
Automatic battery recharging
Microprocessor controlled
Each unit individually tested
3.5 amp AC input
12 V DC output
Because this unit converts AC to DC, this pump will operate for an extended time as a backup unit in case of primary pump failure
Zoeller Charger Control Assembly Specifications
VOLTAGE: 12V AMPS: 10