The Tank Alert® ABW (auto reset, battery backup, wireless) indoor alarm
system provides audio/visual warning of potential threatening liquid level
conditions in lift pump chambers, sump pump basins, holding tanks, sewage,
agricultural, effluent filters and other water applications. It features a
battery operated wirless transmitter that is placed in the tank up to 150
ft. away from the alarm.
When the high water alarm float switch activates, the transmitter sends a
signal and sounds the indoor alarm, warning of a potentially threatening
level condition. The horn can be silenced, but the alarm light remains on
until the condition is remedied. Once the condition is cleared, the alarm
will automatically reset.
SJE-Rhombus Tank Alert ABW Alarm System Typical Application
Lift pump chambers
Sump pump basing
Holding tanks
Sewage
Agricultural
Other non-potable water applications
Specifications
SJE-Rhombus Tank Alert ABW Alarm System Technical Details
NEMA 1 enclosure for indoor use 6 x 4 x 2.25 inches (15.24 x 10.16 x
5.71 cm)
Automatic alarm reset
Red alarm light, green power on light, alarm test switch and horn
silence switch
6 ft. (1.8 meter) power cord
Alarm horn sounds at 87 decibels at 10 feet (3 meters)
If primary power fails, the alarm system continues to operate on the
battery backup
Low battery chirp indicates when battery needs to be replaced (battery
not included)
External terminal block for easy installation of float switch
Loss of signal alarm - after 24 hours without a signal, the red LED
will begin flashing; after 7 days without a signal, the alarm will sound
Switch mechanism operated on low voltage and is isolated from the power
line to reduce the possibility of shock
120 VAC, 60 Hz, 2.4 watts max. (alarm condition)
BATTERY BACKUP POWER: 9 VDC
FLOAT SWITCH CONNECTION TERMINAL (Optional): For float switch
connection only. Do not apply power. (Voltage across terminals is 8-9 VDC)
FCC ID #: SCP TAABW01
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received, including
interference that may cause undesired operation.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Resources
SJE-Rhombus Tank Alert ABW Alarm System Product Resources
PUMPS, WATER & WASTE WATER TREATMENT AND A WHOLE LOT MORE
Dedicated to deliver the highest quality products, and services in the water and wastewater industry, and with the help of our well-trained staff, provide a lasting value to each customer we support... read more
HELPING CUSTOMERS SINCE 1953
As time-tested specialists in water and waste water pumping systems, we are your best choice for pumps and related equipment.