Skip to product information
1 of 1

Littelfuse 601575 Three-Phase Voltage Monitor

Littelfuse 601575 Three-Phase Voltage Monitor


Usually ships within 1 week

SKU : MSR601575

In Stock Quantity:0

:
Brand : Littelfuse/Symcom
Regular price $468.59 USD
Shipping calculated at checkout.

Description

Littelfuse 601575 Voltage Monitor Description

The model 601 is a fully-programmable voltage monitor designed to protect 3-phase motors from loss of any phase (single-phasing), phase reversal, low or high voltage, voltage unbalance, low or high frequency, and rapid cycling. It can be used as a stand-alone product or networked with an RM1000, RM2000, PLC, computer or SCADA system.

When a harmful condition is detected, the 601’s output relay is deactivated after the specified trip delay. The output relay reactivates after power line conditions return to an acceptable level for the programmed restart delay (RD2)

Eleven (11) parameters can be viewed from the three digit LED display or from a networked device:
•Low Voltage •High Voltage •Voltage Unbalance •Low Frequency •High Frequency •Trip Delay for Voltage/Frequency Faults, •Trip Delay for Single-Phase Faults, •Rapid Cycle Timer (RD1), •Restart Delay After all Faults (RD2) •Type of Restart After all Faults (Manual or Automatic).
Six parameters can be viewed as the motor is running:
•L1-L2 Voltage •L2-L3 Voltage •L1-L3 Voltage •Average Voltage •Voltage Unbalance(%) •Voltage Frequency (%).

When used with the RS485MS-2W communications module, the 601 can communicate with most Modbus RTU master devices. Voltage conditions can be monitored and setpoints can be changed remotely using Solutions software, an RM1000, RM2000 or other device.

Littelfuse 601575 Voltage Monitor Typical Applications

  • Fans
  • Compressors
  • HVAC
  • Heat Pumps
  • Well Pumps
  • Sump Pumps
  • Small Conveyor Motors
  • Oil Rigs

Littelfuse 601575 Voltage Monitor Product Features

  • Protects 3-Phase Motors From:
    • Loss of Any Phase (single-phasing)
    • Phase Reversal
    • Low Voltage
    • High Voltage
    • Voltage Unbalance
    • Low Frequency
    • High Frequency
    • Rapid Cycling
  • Built-In 3-Digit Display for Programming, Real-Time Information and Diagnostics
  • Programmable Voltage and Frequency Settings/Parameters
  • Programmable Restart Control (adjustable automatic restart or manual restart)
  • Reset Pushbutton (and optional remote reset pushbutton)
  • 2 Each Separate Programmable Trip Delay Timers and Restart Delay Timers
  • Last Four Faults (with characteristics) Available Via 3-Digit Display, Network or Remote Displays
  • RS-485 Modbus Network Communications
  • Optional Remote Displays Aid in Complying with Arc-Flash Safety Regulations
  • UL and cUL Listed
  • 5-Year Warranty
  • Made in USA

Specifications

Littelfuse 601575 Voltage Monitor Product Specifications

Three-Phase Line Voltage . . . . . . . . . . . . 500-600 VAC

Frequency . . . . . . . . . . . . . . . . . . . . . 50 or 60 Hz

Programmable Operating Points

  • LV-Low Voltage Threshold . . . . . . . . . . .170V (450V*) - HV Setting
  • HV-High Voltage Threshold . . . . . . . . . . LV Setting - 528V (660V*)
  • VUB-Voltage Unbalance Threshold . . . . . . . . . 2-15% or off
  • LF-Low Frequency Threshold . . . . . . . . . 35Hz - HF Setting
  • HF-High Frequency Threshold . . . . . . . . . LF Setting - 75Hz

TD1 - Trip Delay for Voltage/Unbalance/Frequency Faults . . . . . . . . . . . . . . 1-50 seconds

TD2 - Trip Delay for Single-Phase Faults . . . . . . . . . . . . . . 1-50 seconds

RD1 - Rapid Cycle Timer . . . . . . . . . . . . . . . . . . . . . 0, 2-500 seconds

RD2 - Restart Delay After All Faults . . . . . . . . . . . . 2-500 seconds

#RF-Type of Restart . . . . . . . . . . . . Manual or Automatic

ADDR-RS-485 Address . . . . . . . . . . . . A01-A99

Fixed Reset Points

  • Overvoltage Reset . . . . . . . . . . .97% of HV Setting
  • Low Voltage Reset . . . . . . . . . . 103% of LV Setting
  • Voltage Unbalance Reset . . . . . . . . . UB Setting -1%
  • Low Frequency Reset . . . . . . . . . LF Setting +0.6Hz
  • High Frequency Reset . . . . . . . . . HF Setting -0.6Hz

Output Contact Rating . . . . . . . . . . . . . . . . . . . . . 480VA @ 240VAC Pilot Duty

Temperature Range . . . . . . . . . . . . . . . . . . . . . -20° to 70°C (-4° to 158°F)

Accuracy

  • Voltage . . . . . . . . . . . . . . . . . . . . ±1%
  • Timing . . . . . . . . . . . . . . . . . . . . 5% ±1 second

Repeatability

  • Voltage . . . . . . . . . . . . . . . . . . . . ±0.5%
  • Maximum Input Power . . . . . . . . . . . . . . . . . . . . 5 W
  • Transient Protection (Internal) . . . . . . . . . . . . 2500 V for 10 ms

Safety Marks

  • UL . . . . . . UL508 (File #E68520)
  • CSA . . . . . . . . . . . C22.2 No. 14 (File #46510)
  • CE . . . . . . . . . . . IEC 60947-6-2

Weight . . . . . . . . . . . . . . . . . . . . . . . . 19.2 oz.

Mounting Method . . . . . . . . . . . Surface mount (4 - #8 screws) or DIN rail mount

*The 601 can be preprogrammed prior to installation by applying at least 120V to the L1 and L2 terminals.

*575V Model


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Resources

Littelfuse 601575 Voltage Monitor Product Resources

product-resourcesb.png

Littelfuse 601575 Product Specifications

Littelfuse 601575 Installation Bulletin

Littelfuse 601575 Engineering Specifications

Warranty

Loading...
View full details

PUMPS, WATER & WASTE WATER TREATMENT AND A WHOLE LOT MORE

Dedicated to deliver the highest quality products, and services in the water and wastewater industry, and with the help of our well-trained staff, provide a lasting value to each customer we support... read more

HELPING CUSTOMERS SINCE 1953

As time-tested specialists in water and waste water pumping systems, we are your best choice for pumps and related equipment.

  • Wastewater Treatment Systems
  • Sump Pump Systems
  • UV Water Purification & Treatment
  • Irrigation Pump Systems
  • Storm Water Lift Stations
  • Water Well Pump Systems

OUR CUSTOMERS REVIEWS