Troubleshooting a Jet Pump: Low Pressure or Flow

By: Courtney Worst

If you are experiencing low water pressure or low flow, I have included some steps below as part of a jet pump troubleshooting guide to help diagnose the cause.

  1. Check to see if there is water in the pump. If there is no water in the pump, it may have lost its prime. You may have lost prime because the well has run dry, a check valve has gone bad, a foot valve has gone bad, or you have a leak in the suction pipe.
  2. If there is water in the pump, the internal jet may be plugged. Remove the jet injector from the pump and try to clear the obstruction with a coat hanger or something similar.
  3. If you have ruled out the previous possibilities, you may have a motor problem or an internal pump problem. The internal problem could be the impeller, diffuser, or another issue that may require opening up the pump case to explore further.

Shop Replacement Parts

If your troubleshooting points to a failed foot valve or a pump that needs replacing, we have you covered:

Foot Valves

Replacement Jet Pumps

→ Shop our full Jet Pumps collection

Related Guides

Still Need Help?

Do you have further questions about your jet pump or other components in your water system? Our experts are here to help.

Get Expert Help →

You can also call our experts at 855.329.4519 or visit www.rcworst.com.