Model TD Single Phase, Simplex Timed Dosing Pump Control.
The Model TD control panel provides a reliable means of controlling one single phase pump in onsite septic installations. A programmable timer activates a magnetic motor contactor to turn the pump on and off. A low-level cutout float overrides the timer to prevent the pump from running dry. An alarm float activates the audio/visual alarm system indicating a high liquid level.
Common applications include sand filter systems, pressure distribution systems, mound systems, or any application requiring a timed dose.
SJE-Rhombus Model TD - Single Phase Timed Dosing Simplex Motor Contactor Control Panel Features
NEMA 4X Indoor/Outdoor Enclosure
Red Alarm Beacon Provides 360o Visual Check of Alarm Condition (NEMA 1 style uses a door mounted indicator in lieu of a beacon)
Alarm Horn Provides Audio Warning of Alarm Condition (NEMA 1 style uses an internally mounted buzzer in lieu of a horn)
External Alarm Test/Normal/Silence Switch Allows Horn and Light to be Tested and Horn to be Silenced in an Alarm Condition; Alarm Automatically Resets Once Alarm Condition has Been Cleared
Horn Silence Relay
Magnetic Motor Contactor Controls Pump by Switching Electrical Lines
Hand/Off/Automatic (HOA) Switch for Manual Pump Control
Control and Alarm Fuses
Float Switch Terminal Block
Incoming Power Terminal Block
Programmable Timer with Separate Variable Controls (to set on/off times from .05 seconds to 30 hours)
Circuit Breaker Provides Pump Disconnect and Branch Circuit Protection
Spare Fuse
Backplate Label Includes Diagram of Float, Pump and Power Connections
Ground Lug
UL/cUL Listed.
Five-Year Limited Warranty
Components
Panel Components
Enclosure Measures 10 x 8 x 4 inches. NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use).
Magnetic Motor Contactor Controls Pump by Switching Electrical Lines.
HOA Switch for Manual Pump Control.
Control Fuse
Alarm Fuse
Float Switch Terminal Block
Incoming Power Terminal Block
Programmable Timer with Separate Variable Controls Allows for Setting the On and Off Times From .05 Seconds to 30 Hours.
Circuit Breaker Provides Pump Disconnect and Branch Circuit Protection
Spare Fuse
Backplate Label Includes Diagram of Float, Pump, and Power Connections.
Ground Lug
STANDARD ALARM PACKAGE
Red Alarm Beacon Provides 360° Visual Check of Alarm Condition.
Alarm Horn Provides Audio Warning of Alarm Condition (83 to 85 decibel rating).
Exterior Alarm Test/Normal/Silence Switch Allows Horn and Light to be Tested and Horn to be Silenced in an Alarm Condition. Alarm Automatically Resets Once Alarm Condition is Cleared.
Horn Silence Relay (mounted under bracket).
NOTE: Timer Installation Label and Pump/Float Switch Installation Specification Label are Located Inside the Panel on Enclosure Cover.