Prev Next

Myers MW50-21P Sewage Pump 0.5 HP 230V 1 PH Automatic

Price: $760.41
Quantity:
+ -
Usually ships within 2 weeks
SKU: MYRMW5021P


Shipping Weight:
44.0 LBS
Shipping Dimensions
Length: 24 In
Width: 16 In
Height: 16 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Myers MW50 Series Sewage Pump Description

The Myers MW50 Series Sewage Pumps are constructed of the most durable combination of materials to withstand the harshest sewage environments. The non-clog impeller can pass up to 2" solids. Provides the flow and head required for residential and light commercial applications. Models available for manual operation with external controls or automatic operation with tethered, piggyback mechanical float switch.

Myers MW50 Series Sewage Pump Typical Applications

  • Sewage
  • High Capacity Sump
  • Effluent
  • Domestic Wastewater
  • Septic Pumping Applications

Myers MW50 Series Sewage Pump Features

  • Two-Vane Impeller Provides Maximum Efficiency and Eliminates Jamming between Impeller and Volute - Engineered Thermoplastic Composition.
  • Restore Performance Original Performance Standards can be Restored by Easily Replacing a Worn Volute Seal Ring.
  • High-Capacity Handling Passes Full 2" Solids
  • Cool Running Durable, Oil-Filled Motor for Continuous Bearing Lubrication and Maximum Heat Dissipation.
  • Powerful Starts High-Torque, Permanent Split Capacitor (PSC) Motor; No Starting Switches or Relays to Wear Out.
  • Protects Against High Heat Low Amp Draw from Efficient PSC Motor Means Less Heat Build-Up.
  • Longer-Lasting Motor Lower Ball Bearing Eliminates Sleeve Bearing Wear and Reduces Motor Wear.
  • Improved Sealing Long, Flexible Type 6 Seal Provides High-Pressure Sealing with Improved Seal Face Protection by Location.

Myers MW50-21P Series Sewage Pump Specifications

  • VOLTAGE: 1ø, 230V, 60Hz
  • HORSEPOWER: 0.5 HP
  • AMP DRAW (full load): 4.5
  • MOTOR TYPE: Permanent Split Capacitor (PSC)
  • RPM: 1625
  • MAXIMUM HEAD: up to 27'
  • MAXIMUM CAPACITY: up to 135 GPM
  • SWITCH TYPE: Wide-Angle Mercury-Free w/Piggyback Mechanical Float
  • MINIMUM SUMP DIAMETER: Simplex: 24” Duplex: 36”
  • DISCHARGE PIPE SIZE: 2.0" NPT
  • MAXIMUM SOLIDS HANDLING SIZE: 2.0"
  • IMPELLER TYPE: Thermoplastic, Two-Vane
  • CORD LENGTH: 20'
  • BODY CONSTRUCTION: Cast Iron
  • MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)

Myers MW50 Series Sewage Pump Performance Data


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned