Myers MSKV50 Series Submersible Sewage Description

The Myers MSKV50 Submersible Pump is specifically designed to meet the demands of residential wastewater and sewage applications, and the quality standards of the professional plumber. The 2" NPT discharge pump is available with a powerful 1/2 HP performance, in both automatic and manual configurations. The MSKV50 can handle capacities up to 180 gallons per minute and heads over 200 feet.

Myers MSKV50 Series Submersible Sewage Typical Application

Residential Sewage, High-Capacity Sump and Septic Tank Effluent.

Myers MSKV50 Series Submersible Sewage Superior Features

  • Maximize Efficiency: New PSC Motor Offers Same Amp Draw as Before with Better Torque and Flow.
  • Clog Resistant Design: High-Capacity Vortex Thermoplastic Impeller Efficiently Handles up to 2 Inch Spherical Solids and Features a Screenless Bottom Inlet
  • Water Resistant Power Cord: Molded Plug is Available in 10 or 20 Foot Lengths.
  • Cast Iron Construction: Heavy-Duty Design Provides Long Life by Dissipating Heat for Cooler Motor Operation.
  • Low Friction Design: Ball Bearing Design is Oil Filled and Supports the Motor Shaft, Providing Perfect Alignment of Rotor Resulting in Less Friction and Less Frequent Service and Intervals.
  • Mechanical Shaft Seals: Carbon and Ceramic Faced for Long Lasting Life Free of Leaking.
  • Best in Class Warranty: Unparalleled 3 Year Warranty, Your Guarantee of Quality and Performance.

Myers MSKV50M2 Submersible Sewage Pump Specifications

  • VOLTAGE: 1ø, 230V, 60Hz
  • HORSEPOWER: 0.5 HP
  • AMP DRAW (full load): 6.0
  • MOTOR: Oil Filled with Automatic Reset Thermal Overload
  • RPM: 1750
  • MAXIMUM HEAD: up to 22'
  • MAXIMUM CAPACITY: up to 190 GPM
  • SWITCH TYPE: Manual
  • DISCHARGE PIPE SIZE: 2.0" NPT Discharge
  • MAXIMUM SOLIDS HANDLING SIZE: 2.0"
  • IMPELLER TYPE: Thermoplastic, Recessed Vortex
  • CORD LENGTH: 20'
  • CORD SIZE: 16/3; Type: SJTW
  • BODY CONSTRUCTION: Cast Iron
  • MAXIMUM LIQUID TEMPERATURE: 140˚ F

Myers MSKV50 Series Submersible Sewage Pump Curve


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned