Prev Next

SJE-Rhombus Model IFS8 Single Phase 120/208/240V Capacitor Start/Run Duplex Control Panel

Price: $2,450.10
Quantity:
+ -
Usually ships within 4 days
SKU: CP-SJEIFS81W104H8AC17J
Voltage, Pump Amperage, Number of Floats, Special Instructions *
Max: 250 character(s)
Alarm Package:

Enclosure Rating:

Starting Device:

Pump Full Load Amps:

Tool Tip: Horsepower to Amperage

Pump Disconnects:

Float Switch Application:

Option 24 & 29 C-Level Sensor Options:

Float Switch Selection (Option 17) :

Float Switch Selection (Option 31):

Float Switch Selection (Option 33 or 35):

Cord Length:

Panel Options, Select all that are standard and that apply:

Update price


Shipping Weight:
20.0 LBS
Shipping Dimensions
Length: 18 In
Width: 16 In
Height: 8 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

sjerhombuslogo6002018.jpg

SJE-Rhombus Model IFS Single Phase Duplex Capacitor (Start/Run) Panel Description

Single Phase, Duplex Demand Dose, Float or C-Level™ Controlled System for Pump Control and System Monitoring.

The IFS single phase duplex capacitor (start/run) control panel is designed to alternately control two 120/208/240 VAC single phase pump in water and sewage applications. The IFS single phase simplex capacitor (start/run) control panel features an easy-to-use color LCD interface located in the inner door for programming and system monitoring. The panel configuration can be easily converted in the field to either a timed dose or demand dose through the LCD interface.

The panel can easily be changed in the field to utilize floats, Sub-X LT Transmitter or the C-Level Sensor for continuous monitoring. The Sub-X LT Transmitter or the C-Level Sensor sense the level in the tank and sends a signal to the panel. Pump activation levels can be adjusted by using the LCD interface.

SJE-Rhombus Model IFS Single Phase Duplex Capacitor (Start/Run) Panel Features

    LCD Interface Features:
  • Full Color Graphics and Menu Navigation Encoder for Easy Setup
  • Touch Safe Housing
  • Pump Hand/Off/Auto Control Selectable via Menu Navigation
  • Sub-X™ LT Transmitter, C-Level Sensor or Float Operation Selectable
  • Demand or Timed Dose Operation Selectable via Menu Navigation
  • Tank Level Indication and Setpoint Monitoring At-A-Glance
  • Lead Pump is Easily Identified by a Graphic Ring around the Current Lead Pump Regardless of Control Mode (timed dose or demand)
  • Displays Remaining Time in Timed Dose Mode
  • RJ45 Communication Connector
  • Flashing Function for Alarm Beacon and Horn (configurable)
  • Manual Alarm Reset (configurable)
  • Thermal Cutout and Seal Failure Module (Optional)
  • UL/cUL Listed.
  • Five-Year Limited Warranty on Panel. This Express Warranty does not Apply to the Motor Start Kit Components. SJE Rhombus Will Warranty Motor Start Kit Components Supplied by SJE Rhombus for One Year. SJE Rhombus makes no Warranties of Any Type with Respect to Motor Start Kits Supplied by Customer.
  • Two-Year Limited Warranty on C-Level™ Sensor

SJE-Rhombus Model IFS Single Phase Duplex Capacitor (Start/Run) Panel Specifications

    Panel Components:
  1. Enclosure Base Measures 18 X 16 X 8 inches (45.72 x 40.64 x 20.32 cm) NEMA4X Fiberglass for Outdoor or Indoor Use
  2. Red Alarm Beacon Provides 360° Visual Check of Alarm Condition.
  3. Circuit Breakers Provides Pump Power Disconnect and Branch Circuit Protection Included as Standard on all Panels
  4. Option 9_A - Adjustable Overload Relay
  5. Sub-X™ LT Transmitter, C-Level™ Sensor and Float Connection Terminal Blocks
  6. Controller Features:
    1. Incoming Control/Alarm Power/System Status Green LED Indicators Illuminate if Control/Alarm Power is Present and Controller is Operating*
    2. Controller Status Green LED Indicators for Power/Active* Float Input Status, Pump Run, C-Level Active*
    3. Normally Open Auxiliary Alarm Contacts Included as Standard
    4. Control Power On/Off Switch
    5. Green LED Pump Run Indicators Illuminate When Pump is Called to Run*
    6. Control Panel Able to Operate if LCD Interface Fails or is Disconnected
    7. Touch Safe Housing
  7. Modbus Port (RJ45) for Future Expansion - eg. Remote Monitoring, Valve Control, In-Site®, Logging, ect.
  8. Option 5AE - Thermal Cutout/Heat Sensor & Seal Failure Module
  9. Large Incoming Power Connection Terminal Block
  10. Alarm Horn Provides Audible Warning of Alarm Condition (Not Shown)
  11. Exterior Alarm Test/Silence Push Button Allows Horn and Light to be Tested and Horn to be Silenced in an Alarm Condition; Alarm Automatically Resets Once Alarm Condition is Cleared (Not Shown)

*In Fault Condition. LED Indicators will be Red

NOTE: Options, Voltage, and Amp Range Selected May Change Enclosure Size and Component Layout.

NOTE: Schematic/Wiring Diagram and Pump Specification Label are Located Inside the Panel

    LCD Interface Features:
  • Full Color Graphics and Menu Navigation Encoder for Easy Setup.
  • Touch Safe Housing
  • Pump Hand/Off/Auto Control Selectable via Menu Navigation
  • Sub-X™ LT Transmitter, C-Level™ Sensor or Float Operation Selectable
  • Demand or Timed Dose Operation Selectable via Menu Navigation
  • Tank Level Indication and Setpoint Monitoring At-A-Glance
  • Lead Pump is Easily Identified by a Graphic Ring Around the Current Lead Pump Regardless of Control Mode (timed dose or demand)
  • Displays Remaining Time in Timed Dose Mode
  • RJ45 Communication Connector
  • Flashing Function for Alarm Beacon and Horn (configurable)
  • Manual Alarm Reset (configurable)
  • Thermal Cutout and Seal Failure (optional)

WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

SJE Rhombus Limited Warranty Policy

Five-Year Limited Warranty Policy We Stand Behind Our Products!

Effective for products manufactured after January 1, 2014

SJE-Rhombus warrants to the original consumer that this product shall be free of manufacturing defects for five years* after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-Rhombus will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-Rhombus.

THE FIVE-YEAR LIMITED WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENTS. SJE-RHOMBUS WILL WARRANTY MOTOR START KIT COMPONENTS, SUPPLIED BY SJE-RHOMBUS FOR ONE YEAR. SJE-RHOMBUS MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO MOTOR START KITS SUPPLIED BY A CUSTOMER.

SJE-Rhombus warrants to the original consumer that this product shall be free of manufacturing defects for five years* after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-Rhombus will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-Rhombus.

THE FIVE-YEAR LIMITED WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENTS. SJE-RHOMBUS WILL WARRANTY MOTOR START KIT COMPONENTS, SUPPLIED BY SJE-RHOMBUS FOR ONE YEAR. SJE-RHOMBUS MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO MOTOR START KITS SUPPLIED BY A CUSTOMER.

ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN.

This warranty does not apply to: (a) damage due to lightning or conditions beyond the control of SJE-Rhombus; (b) defects or malfunctions resulting from units not installed, operated, or maintained in accordance with instructions provided, applicable local codes, ordinances, or accepted trade practices; (c) failures resulting from abuse, misuse, accident, or negligence; or (d) units repaired and/or modified without prior authorization from SJE-Rhombus.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-Rhombus, or such place as designated by SJE-Rhombus. Contact customer service at 1-888-DIAL-SJE (1-888-342-5753) for a Return Materials Authorization number (RMA) on any product being returned for a warranty claim.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS SHALL NOT, IN ANY MATTER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

*Build-A-Panel™ Plus Control Panels and Engineered Custom panels carry a two-year limited warranty (or as quoted). The pressure transducer included with VARIOspeed® products carries a one-year limited warranty.

We've been helping customers since 1953

Trust Guard Security Scanned