Prev Next

Luminor LK5-A42 K2 5.0 Commercial UV Water System 400 GPM 230V

Price: Call For Details
Quantity:
+ -
Usually ships within 2 weeks
SKU: LUMLK5-A42
Model/Flow Rate:


Update price


Shipping Weight:
50.0 LBS
Shipping Dimensions
Length: 45 In
Width: 7 In
Height: 8 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Luminor K2 5.0 Commercial UV System

LUMINOR's K2 line of disinfection systems are specifically designed and built to handle the challenging environments of process and manufacturing industries as well as pool and leisure applications.

Unsure about needing a UV sensor or if regulations require you to add a sensor? There is no need to replace the entire system....simply add a UV sensor module to the K2 5.0 reactor  as it comes with an integral sensor port built in! Plug the optional UV sensor into the pre-wired controller and the UV intensity will be displayed on the LCD output.

Constructed with highly polished 316L stainless steel reactors and stainless steel enclosures, K2 5.0 uses proven low pressure amalgam (LP-AM) lamp technology for maximum power density and efficiency all in a small footprint.

Controlling microbiological (bacteria & virus) issues in water (or other viscous fluids), including E.coli, Cryptospordium and Giardia lamblia is safe and simple with LUMINOR UV systems. UV does not affect the aesthetic quality of fluid and the process does not add anything to the fluid, nor create any disinfection by-products.

Covering a wide variety of applications in both regulated and unregulated markets, K2 offers environmentally friendly disinfection at lower capital and operating costs than traditional disinfection solutions.

Luminor K2 5.0 Commercial UV Applications:

Food & Beverage, Pharmaceutical, Swimming Pools, Water Reuse, Ultrapure, Recreational Water, Aquaculture & Municipal

Luminor K2 5.0 Commercial UV System Product Features:

  • Modular 304 Stainless Steel Control Panel with LCD Display for Remaining Lamp Life, Total Running Hours, Audible & Visual Lamp Failure, Remote-On and Dry Contacts.
  • 316L Stainless Steel, Polished Reactors with Flanged End-Plate.
  • Designed & Manufactured to ASME Pressure Vessel Standards.
  • Flow Rates Stated as 95% UVT at a Dose of 30 mJ/cm²
  • User Friendly Bayonet Style Lamp Connectors (quick 1/4 turn removal with no extra tools needed).
  • True Gland Seal Retaining Nuts with Positive Stop.
  • Reliable, Industry Proven Low Pressure Amalgam (LP-AM) Coated UV Lamps with Ceramic Bases for Durability and a 12,000 Hour Lamp Life.
  • Constant Current Electronic Ballasts.
  • HOT WATER (HW): For Use in Hot Water Applications Including Recirculation Loops, Showers, Cooling Towers, ect., Designed for the Reduction of Legionella.
  • TOC: For the Reduction of TOC (Total Organic Carbon) using UV Lamps at 185 nm Output.

Luminor K2 5.0 Commercial UV System Control Features:

  • Individual Lamp Status Indicators (visual & audible failure indicators).
  • Lamp Age Monitor (visual & audible failure indicators).
  • Lamp Cycle Counter (tracks total on-off lamp cycles).
  • Service time Monitor (tracks total system running time).
  • Chamber Temperature Monitor (monitors high temperatures and no flow conditions).
  • Panel Temperature Monitor (protects electronic circuits from extreme temperatures).
  • Remote On/Off Feature (allows reactor to be controlled remotely and timed with other system components).
  • Automatic Reactor Shut-Down (user configurable).
  • Dry Contact Outputs.
    • Minor Alarm (NO/NC)
    • Major Alarm (NO/NC)
    • Reactor Ready (valve control feature)(NO/NC)
  • Major Alarm Output (audible & visual)
  • Minor Alarm Output (audible & visual).

Luminor K2 5.0 Commercial UV System Specifications:

  • System: LK5-A42, LK5-A42-HW & LK5-A42-TOC
  • Application: POE (point-of-entry)
  • Flow Rate: 400GPM (1500 lpm), 180GPM (681 lpm) & 80GPM (303 lpm)
  • Inlet/Outlet Port Size: 4.0” Flange
  • Electrical: 230 V
  • Power Watts: 900W
  • UV Lamp for LK5-A42: RL-1000A (4 required)
  • UV Lamp for LK5-A42-HW: RL-100A-HW (4 required)
  • UV Lamp for LK5-A42-TOC: RL-1000A-TOC (4 required)
  • Quartz Sleeves: RQ-K2 (4 required)
  • Controller: RB-K22


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

LIMITED WARRANTY STATEMENT

Products manufactured by LUMINOR Environmental Inc. (LUMINOR) are warranted to the original user only to be free of defects in material and workmanship for a period as specified below. This warranty only applies to the original purchaser and is not transferable.

UV SYSTEMS

Ten (10) year Limited Warranty on the stainless steel reactors, from the date of original purchase, or installation (proper documentation required for verification).

UV LED SYSTEMS

GLACIER UV LED modules are covered by a One (1) year Limited Warranty, from the date of original purchase (proper documentation required for verification)

ELECTRONICS

Three (3) year Limited Warranty on the ballasts and controllers, from the date of original purchase, or installation (proper documentation required for verification).

UV LAMPS, UV SENSORS & QUARTZ SLEEVES

One (1) year Limited Warranty on all LUMINOR ultraviolet lamps, from the date of original purchase, or installation (proper documentation required for verification).

LUMINOR warrants that it will repair, replace or refund, at LUMINOR’s sole option, any ultraviolet system or component that is defective in materials or workmanship for the period as outlined above, subject to the “Limitations of Warranty” as outlined below. LUMINOR's liability under this warranty shall be limited to repairing or replacing at LUMINOR's option, without charge, F.O.B. LUMINOR’s factory or authorized service depot, any product that LUMINOR manufactures. LUMINOR will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by LUMINOR are subject to the warranty provided by the manufacturer of said products and not by LUMINOR’s warranty. LUMINOR will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with LUMINOR’s printed installation and operating instructions.

LIMITATIONS OF WARRANTY

This warranty does not apply to any of the following:

  • Water Quality Parameters lie outside of the following range:
  • Hardness 120 mg/L (7 gpg)
  • Iron 0.3 mg/L (ppm)
  • Manganese 0.05 mg/L (ppm)
  • Tannins 0.1 mg/L (ppm)
  • Turbidity 0.1 NTU
  • Transmittance (UVT) 75% (50% for Low-UVT systems)

A product that has been incorrectly installed according to the technical installation manual.

A product that has been modified in any manner, unless approved by the manufacturer.

A product where the serial number has been altered defaced or removed.

Damage caused by the use of parts that are not compatible, suitable and/or authorized by LUMINOR for use with the product (e.g. non-original lamps or sleeves).

Damage caused during shipment of the product.

Water damage is found inside ballast housing or controllers.

Product is installed outdoors in direct contact with the environment (rain).

Product is installed in freezing temperatures.

Product is used in conditions that exceed LUMINOR’s specifications.

TO GET WARRANTY SERVICE

To obtain service under this warranty, you must first contact LUMINOR Customer Service at 855-837-3801 (519-837-3800 outside of the US or Canada) to obtain a Warranty Return Authorization.

You will then need to return the product through the LUMINOR Dealer or Distributor where the product was originally purchased, together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise provided, the Dealer or Distributor will contact LUMINOR for instructions on returning the product. Any defective product to be returned to LUMINOR must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Material Authorization must be included if so instructed.

LUMINOR WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLATION, USE, OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE.

THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY MADE BY LUMINOR WITH RESPECT TO THE PRODUCT, AND IS GIVEN IN LIEU OF ANY OTHER WARRANTY. TO THE EXTENT ALLOWED BY APPLICABLE LAW, ANY AND ALL EXPRESS OR IMPLIED WARRANTIES NOT SET FORTH HEREIN ARE WAIVED AND DISCLAIMED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE. LUMINOR LIABILITY UNDER THIS LIMITED WARRANTY IS LIMITED SOLELY TO THOSE LIABILITIES SET FORTH ABOVE. IN THE EVENT THAT ANY PROVISION OF THIS LIMITED WARRANTY SHOULD BE OR BECOME INVALID OR UNENFORCEABLE UNDER APPLICABLE LAW, THE REMAINING TERMS AND CONDITIONS HEREOF SHALL REMAIN IN FULL FORCE AND EFFECT AND SUCH INVALID OR UNENFORCEABLE PROVISION SHALL BE CONSTRUED IN SUCH A MANNER AS TO BE VALID AND ENFORCEABLE.

We've been helping customers since 1953

Trust Guard Security Scanned