Myers Model VS20 Grinder Pump Description
The Myers VS20 Series is the newly innovative 2 HP Submersible Grinder Pump is designed specifically for use in today's complex wastewater environment. It features an advanced cutting technology and semi-open impeller design to effectively macerate typical domestic sewage solids into a fine slurry.
Myers Model VS20 Grinder Pump Superior Features
- Cable Entry System:
- Optional Quick Disconnect Cord Available for Ease of Maintenance.
- Cable Jacket Sealed by Compression Fitting; Individual Wires Sealed by Compression Grommet for Double Seal Protection Against Water Ingress.
- Replace Power Cord without Disturbing Motor for Ease of Maintenance.
- Oil-Filled Motor:
- Maximizes Heat Dissipation; Provides Constant Bearing Lubrication for Long Life.
- High Torque Start/Run Capacitor for Single or Three-Phase Motors, Assured Starting Under Heavy Loads.
- Heavy 416 SST Shaft:
- Corrosion Resistant, Reduces Shaft Deflection for Long Life.
- Lower Double Row Ball Bearings:
- Absorb Both Axial and Radial Loads for Increased Durability.
- Double Mechanical Shaft Seals:
- In Oil-Filled Seal Chamber for Continuous Lubrication, Superior Motor Protection.
- Seal Leak Probe:
- Located in Seal Chamber Instead of Motor Area for Truly Early Warning of Water Leaks. Allows Corrective Action before Costly Motor or Bearing Failure Occurs.
- Activates Warning Light in Control Panel.
- SST Semi-Open Impeller:
- Provides Improved Performance, Resists Clogging.
- Pump-Out Vanes Help Keep Trash from Sea, Reduces Pressure at Seal Face for Longer Life.
- Axial Cutter System:
- Constructed of 440 SST Hardened to 57-60Rc for Long Life.
- Easily Replaceable without Dismantling Pump.
- Volute Case:
- Cast Iron 1¼" NPT Vertical Flanged Discharge.
Myers VS20-43-35 Grinder Pump Specifications
- VOLTAGE: 3ø, 460V, 60Hz
- HORSEPOWER: 2.0 HP
- AMP DRAW (full load): 4.2
- MOTOR TYPE: Oil-Filled for Maximum Heat Dissipation and Constant Bearing Lubrication
- RPM: 3450
- MAXIMUM HEAD: up to 139'
- MAXIMUM CAPACITY: up to 31 GPM
- SWITCH TYPE: Manual
- MINIMUM SUMP DIAMETER: Simplex; 24" Duplex; 36"
- DISCHARGE PIPE SIZE: 1-1/4" Flanged, Vertical
- IMPELLER TYPE: Stainless Steel, Semi-Open
- CORD LENGTH: 35'
- CORD SIZE: 12-5
- BODY CONSTRUCTION: Cast Iron
- MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)
- CONTROL BOX REQUIRED
Myers Model VS20 Grinder Pump Curve
WARNING:
Cancer and Reproductive Harm - www.P65Warnings.ca.gov
STANDARD LIMITED WARRANTY
Pentair Myers® warrants its products against defects in material and workmanship for a period of 12 months from the
date of shipment from Pentair Myers or 18 months from the manufacturing date, whichever occurs first – provided
that such products are used in compliance with the requirements of the Pentair Myers catalog and technical manuals
for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids.
During the warranty period and subject to the conditions set forth, Pentair Myers, at its discretion, will repair or
replace to the original user, the parts that prove defective in materials and workmanship. Pentair Myers reserves the
right to change or improve its products or any portions thereof without being obligated to provide such a change or
improvement for prior sold and/or shipped units.
Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of startup
through the Pentair Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m.
Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices
must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower
seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Myers be responsible for the cost
of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the
factory or an authorized Pentair Myers service facility.
This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or
maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident
or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that
are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is
moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and
manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Myers or an authorized
Pentair Myers service provider; (h) to any unit that has been repaired using non factory specified/OEM parts.
Warranty Exclusions: PENTAIR MYERS MAKES NO EXPRESS OR IMPLIED WARRANTIES THAT EXTEND BEYOND
THE DESCRIPTION ON THE FACE HEREOF. PENTAIR MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES
OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.
Liability Limitation: IN NO EVENT SHALL PENTAIR MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL,
INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY PENTAIR MYERS
PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER
INSTALLATION. PENTAIR MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR
IMPROPER INSTALLATION. PENTAIR MYERS RECOMMENDS INSTALLATION BY PROFESSIONALS.
Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or
consequential damages and therefore such limitations may not apply to you. No warranties or representations at any
time made by any representatives of Pentair Myers shall vary or expand the provision hereof.