Prev Next

Myers SS75-90-02 Ranger Series 4" Submersible Well Pump End 90 GPM 7.5 HP

Price: $2,117.27
Quantity:
+ -
Usually ships within 2 weeks
SKU: MYRSS759002


Shipping Weight:
33.0 LBS
Shipping Dimensions
Length: 70 In
Width: 5 In
Height: 5 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Myers 4" Submersible Ranger Series Pump End Description

The Ranger Series 90GPM Stainless Steel 4" High-Flo Submersible Pumps deliver efficient and dependable performance even in rough, aggressive water. New stack design delivers better efficiency and head per stage than previous model.

Myers 4" Submersible Ranger Series Pump End Application

  • Water Systems - Irrigation, Industrial, Commercial, Multiple Housing and Farm Clean Water Use.

Myers 4" Submersible Ranger Series Pump End Features

  • Discharge: Heavy-Duty 300 Grade Stainless Steel Construction Provides Smooth Water Passage to Column Pipe. Large Wrench Flats and Rope Hole.
  • Top Bearing: Self-Lubricated Top Bearing Ensures Long Bearing Life.
  • Impellers: 20% Glass-Reinforced Noryl to Resist Abrasives and Provide Smooth Water Passage for Minimal Friction Loss.
  • Diffuser Bearing: Bearings at Each Stage Provide Radial Protection and Stability and Excellent Resistance to Sand Damage.
  • Motor Bracket: 300 Grade Precision Cast Stainless Steel. Incorporates and Efficient Hydraulic Design for Maximum Volume and Access to Motor Mounting Nuts.
  • Shaft: 300 Grade "Treated" Stainless Steel Pump Shaft is Corrosion-Resistant. The Hex Shape Offers Generous Impeller Drive Surfaces.
  • Motor Coupling: Pressed-On, Sintered 300 Grade Stainless Steel for Maximum Corrosion Resistance Provides Trouble-Free Transfer of Power Between Motor and Pump Shaft.
  • Shell: Heavy-Gauge, 300 Series Stainless Steel Pump Shell is Durable and Offers High Corrosion Resistance.
  • Intake Screen: 300 Series Stainless Steel Material Offers Maximum Corrosion Resistance and Protects against Damaging Solids Entering the Pump.

Myers SS75-90-02 Ranger Series Pump End Specifications

  • DISCHARGE SIZE: 2.0” NPT
  • NOMINAL FLOW RATING: 90 GPM
  • HORSEPOWER: 7.5 HP
  • MAXIMUM CAPACITY: up to 124 GPM
  • MAXIMUM HEAD: up to 400'
  • STAGES: 19
  • IMPELLER DESIGN: Floating Stack
  • IMPELLER MATERIAL: Engineered Composite
  • BODY MATERIAL: 304 Stainless Steel

Myers 4" Submersible Ranger Series Pump End Curve


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Myers 4" Submersible Ranger Series Pump End Product Resources

product-resourcesb.png

Download Myers Ranger Series Specifications

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned