Myers 3RMW Series Dual Seal Vortex Wastewater Pump Description

Myers 3RMW Submersible Wastewater Vortex Pumps are the right choice when difficult to pump fibrous or stringy solids are to be expected. The 3RMW series provides smooth, vibration-free operation over the entire performance curve.

Myers 3RMW Series Dual Seal Vortex Wastewater Pump Applications

Light and medium commercial applications

Myers 3RMW Series Dual Seal Vortex Wastewater Pump Features

  • Motor Housing: Cast Iron for Efficient Heat Transfer and Corrosion Resistance.
  • Motor: 1, 1-1/2, 2 and 3 HP Single or Three Phase, 60 Hz, 3450 RPM. 1-1/2, 2 and 3 HP Single or Three Phase, 60 Hz, 1750 RPM. Single Phase PSC Motors Have Built-In Winding Overload Protection, Oil-Cooled and Lubricated.
  • Ball Bearings: Upper and Lower Ball Bearings Support Rotor and Take Radial and Thrust Loads.
  • Seal Leak Probes: Detect Water Leakage in Seal Housing. Activates Warning Light (Dual Seal Models Only) .
  • Pump Out Vanes: Help Keep Trash From Seal, Reduces Pressure at Seal Faces.
  • Shaft Seals: Carbon and Ceramic Faces, Optional Tungsten Carbide.
  • Recessed Open Vane Impeller: Ductile Iron Construction.
  • High Efficient Cast Iron Volute: Corrosion Resistant 3" Flanged Horizontal Discharge with Legs. Recessed Impeller Greatly Increases Bearing Life by Reducing Radial Load.
    Operates Without Vibration or Cavitation Over Entire Performance Curve. Operates Near Shutoff Without Harming Pump.
  • Power and Control Cords: Jacket Sealed with Compression Fittings. Individual Wires Potted with Epoxy to Prevent Wicking in Case of Cord Damage.

Myers 3RMW15DM2-23 Dual Seal Vortex Wastewater Pumpump Specifications

  • VOLTAGE: 3ø, 230V, 60Hz
  • HORSEPOWER: 1.5 HP
  • AMP DRAW (full load): 8.0
  • MOTOR TYPE: Enclosed, Oil Cooled Induction
  • RPM: 3450
  • MAXIMUM HEAD: up to 39'
  • MAXIMUM CAPACITY: up to 200 GPM
  • SWITCH TYPE: Manual
  • MINIMUM SUMP DIAMETER: 48"
  • DISCHARGE PIPE SIZE: 3.0" Flanged, Horizontal
  • MAXIMUM SOLIDS HANDLING SIZE: 2.0"
  • IMPELLER TYPE: Ductile Iron, Recessed, Open Vane
  • IMPELLER DIAMETER: 3.50"
  • CORD LENGTH: 20'
  • CORD SIZE: 16-4; Type SOOW / SJOOW
  • BODY CONSTRUCTION: Cast Iron, Class 30, ASTM A48
  • MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)
  • CONTROL PANEL REQUIRED

Myers 3RMW Series Dual Seal Vortex Wastewater Pump Performance Curve


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned