Prev Next

Myers 3MW30M4-53 Solids Handling Pump 3.0 HP 575V 3PH 1750 RPM 20' Cord

Price: $3,544.00
Quantity:
+ -
Usually ships within 4 weeks
SKU: MYR3MW30M4-53


Shipping Weight:
115.0 LBS
Shipping Dimensions
Length: 20 In
Width: 20 In
Height: 24 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Myers 3MW Series Solids Handling Pump Description

The heavy-duty Myers 3MW Series Solids Handling Wastewater Pumps are designed for use in residential raw sewage and light commercial applications. 3MW pumps are available in single and dual seal configurations. The enclosed two-vane impeller provides high efficiency pumping and easily handles trashy solids normally found in sewage applications. This series is offered with vertical discharge and easily adapts to a quick-disconnect slide rail system.

Myers 3MW Series Solids Handling Pump Applications

  • Residential and Commercial Sewage/Dewatering
  • High Capacity Sump
  • Effluent
  • Sewage Lift Stations

Myers 3MW Series Solids Handling Pump Features

  • Motor Housing: Cast Iron for Efficient Heat Transfer and Corrosion Resistance.
  • Motor: 1, 1-1/2, 2 and 3 HP Single or Three Phase, 60 Hz, 3450 RPM. 1-1/2, 2 and 3 HP Single or Three Phase, 60 Hz, 1750 RPM. Single Phase PSC Motors have Built-In Winding Overload Protection, Oil-Cooled and Lubricated.
  • High Efficient Cast Iron Volute: Corrosion Resistant. 3” NPT Vertical Discharge with Legs.
  • Enclosed Two Vane Impeller: High Efficiency. Standard Cast Iron Construction.
  • Volute/Impeller Seal Ring: Maintains High Efficiency and Reduces Recirculation. Replaceable.
  • Pump Out Vanes: Help Keep Trash from Seal, Reduces Pressure at Seal Faces.
  • Ball Bearings: Upper and Lower Ball Support Rotor. Take Radial and Thrust Loads.
  • Power and Control Cords: Jacket Sealed with Compression Fittings. Individual Wires Potted with Epoxy to Prevent Wicking in Case of Cord Damage.
  • Shaft Seals: Carbon and Ceramic Face. Dual Tandem Seals Extends Motor Life. Optional Tungsten Carbide.
  • Seal Leak Probes: Optional Probes (Dual Seal Only) Detect Water Leakage in Seal Housing. Activates Warning Light.

Myers 3MW30M4-53 Solids Handling Pump Specifications

  • VOLTAGE: 3ø, 575V, 60Hz
  • HORSEPOWER: 3.0 HP
  • AMP DRAW (full load): 5.5
  • MOTOR: Enclosed, Oil Cooled Induction
  • RPM: 1750
  • MAXIMUM HEAD: 49’
  • MAXIMUM CAPACITY: 330 GPM
  • SWITCH TYPE: Manual
  • MINIMUM SUMP DIAMETER: Duplex = 48"
  • DISCHARGE PIPE SIZE: 3.0" Flanged
  • MAXIMUM SOLIDS HANDLING SIZE: 2.5"
  • IMPELLER TYPE: Ductile Iron, class 65 ASTM A536, Enclosed 2-Vane Impeller
  • IMPELLER DIAMETER: 7.00" Standard
  • CORD LENGTH: 20' Type SOW/SOWA
  • BODY CONSTRUCTION: Cast Iron
  • MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)
  • CONTROL BOX REQUIRED

Myers 3MW Series Solids Handling Pump Performance Curve

3mw_1750rpm_pumpcurve.jpg


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned