Prev Next

Myers 2NFL52-8-P4 Submersible Rustler Series Pump 8 GPM 0.5 HP 230V 2-Wire 1PH

Price: $1,009.01
Quantity:
+ -
Usually ships within 2 weeks
SKU: MYR2NFL52-8-P4


Shipping Weight:
25.0 LBS
Shipping Dimensions
Length: 6 In
Width: 6 In
Height: 25 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Myers 4" Submersible Rustler Series Pump Description

Precision-Engineered, corrosion-resistant pumps in 5, 7/8, 10/12, 20 and 30 GPM deliver efficient, dependable performance even in rough, aggressive water. Head up to 650 feet and capabilities to 45 GPM. Built to deliver long-term, trouble-free service.

These pumps feature the proven SignaSeal staging system. Floating impeller design resists sand and reduces sand locking.

Myers 4" Submersible Rustler Series Pump Application

  • Residential Water Systems
  • Industrial Water Systems
  • Commercial Water Systems
  • Multiple Housing and Farm Clean Water Use

Myers 4" Submersible Rustler Series Pump Features

  • Proven Staging System: Our proven SignaSeal Staging System Incorporates a Harder-than-Sand Ceramic Wear Surface that when Incorporated with our Floating Impeller Design, Greatly Reduces Problems with Abrasives, Sand Lock-Up and Running Dry.
  • Discharge: Corrosion-Resistant Fiberglass-Reinforced Thermoplastic for Durability in Aggressive Water. Large Octagon Wrench Area for Ease of Installation.
  • Discharge Bearing: Exclusive Self-Lubricating Nylatron Bearing Resists Wear from Sand.
  • Intake: Corrosion-Resistant Fiberglass-Reinforced Thermoplastic for Durability in Aggressive Water.
  • Shaft: Positive Drive from 7/16" Hexagonal Heavy-Duty 300 Grade Stainless Steel.
  • Coupling: Stainless Steel Press Fit to Pump Shaft. Couples to all Standard NEMA Motors.
  • Shell: Crimped Shell.
  • Hardware: All Screws, Washers and Nuts are Corrosion-Resistant 300 Grade Stainless Steel.
  • Check Valve: Spring-Loaded Check Valve.
  • Cable Guard: Corrosion-Resistant Stainless Steel Guard Protects Motor Leads. Tapered Ends Prevent Pump from Catching on Well.
  • Intake Screen: Molded-In Screen.
  • Pentek XE Series Motor: 2 and 3 Wire NEMA Standard all Stainless Steel Construction Water-Filled Motors.

Myers 2NFL52-8-P4 Rustler Series Pump Specifications

    Water Well Motor
  • BODY CONSTRUCTION: 304 Stainless Steel
  • HORSEPOWER: 0.5 HP
  • VOLTAGE: 1ø, 230V
  • FULL LOAD AMPS: 4.7
  • LEAD: 2-Wire
  • Water Well Pump End
  • DISCHARGE SIZE: 1.25" NPT
  • NOMINAL FLOW RATING: 8 GPM
  • HORSEPOWER: 0.5 HP
  • MAXIMUM CAPACITY: 13 GPM
  • MAXIMUM HEAD: 300 ft.
  • STAGES: 9
  • IMPELLER DESIGN: Floating Stack
  • IMPELLER MATERIAL: Acetal
  • BODY MATERIAL: Stainless Steel

Myers 4" Submersible Rustler Series Pump Curve


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned