{"title":"Seal Fail Circuit","description":"","products":[{"product_id":"zoeller-10-0395-model-g840-shark-control-panel-auto-reversing-circuit-simplex-460v-3ph","title":"Zoeller 10-0395 Model G840 \"Shark\" Control Panel Auto Reversing Circuit Simplex 460V 3PH","description":"\u003ch3\u003e\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\u003c\/h3\u003e\n\u003ch3\u003eZoeller Control Panel 840 Simplex Description\u003c\/h3\u003e\n\u003cp\u003eThe control panel can be housed in a NEMA 4X enclosure and be of a simplex design which controls a single pump from a 3-float system or a duplex design which controls two pumps in an alternating lead\/lag cycle sequence from a 3 or 4-float system. The panel contains the required starting, control, \u0026amp; alarm circuits. Rated motor starters and circuit breakers are required for each pump. The 115 volt control circuit will have short circuit protection. The panel will have pump run pilot light(s) and pump alarm selector switches. The panel will be equipped with circuit(s) which automatically reverses the direction of the cutter blades. A seal leak indicator light is required as well as a thermal cut-out connection for 3 phase systems. A padlock hasp will be provided. High water conditions will be indicated by a visible light with polycarbonate cover. Numbered terminal strips are required. A wiring schematic and trouble shooting guide will be included with each panel. The panel will be UL listed and be labeled as such.\u003c\/p\u003e\n\u003cp\u003eZoeller Control Panel w\/Automatic Reversing Circuit Std. Simplex. (840 only) 10-0395 fits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/rcworst.com\/products\/zoeller-840-0008-model-g840-shark-auto-reversing-grinder-pump-2-hp-460v-3ph-20-cord-nonautomatic\" target=\"_blank\" title=\"Zoeller 840-0008 Model G840 Shark Auto Reversing Grinder Pump 2HP 460V 3PH 20' Cord Automatic\" rel=\"noopener\"\u003eZoeller 840-0008 Model G840 Shark Auto Reversing Grinder Pump 2HP 460V 3PH 20' Cord Automatic\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZoeller Control Panel 840 Simplex Features and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA 4X Outdoor Rating\u003c\/li\u003e\n\u003cli\u003eStarting, Control, and Alarm Circuits\u003c\/li\u003e\n\u003cli\u003eThermal Cut-Out Circuit (3 phase only)\u003c\/li\u003e\n\u003cli\u003eCapacitors and Motor Starting Relay On\u003c\/li\u003e\n\u003cli\u003eSingle Phase\u003c\/li\u003e\n\u003cli\u003eMotor Protective Switch (circuit breaker \/ adj overloads) and Rated Motor Contactor (3 Phase)\u003c\/li\u003e\n\u003cli\u003eAlternating Circuit (duplex)\u003c\/li\u003e\n\u003cli\u003eAutomatic Reversing Circuit\u003c\/li\u003e\n\u003cli\u003eHigh Water Alarm Light\u003c\/li\u003e\n\u003cli\u003eInternal Seal Leak Light\u003c\/li\u003e\n\u003cli\u003eHOA Switches and Pilot Light(s)\u003c\/li\u003e\n\u003cli\u003eTerminal Strips\u003c\/li\u003e\n\u003cli\u003ePadlock Hasp\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFLOAT SWITCHES NOT INCLUDED WITH THREE PHASE\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323195269437,"sku":"ZLR10-0395","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_a0c9eb84-093a-49b6-9935-dae90fc5a5df.jpg?v=1725383418"},{"product_id":"zoeller-10-0396-model-ba840-shark-control-panel-auto-reversing-circuit-simplex-575v-3ph","title":"Zoeller 10-0396 Model BA840 \"Shark\" Control Panel Auto Reversing Circuit Simplex 575V 3PH","description":"\u003ch3\u003e\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\u003c\/h3\u003e\n\u003ch3\u003eZoeller Control Panel 840 Simplex Description\u003c\/h3\u003e\n\u003cp\u003eThe control panel can be housed in a NEMA 4X enclosure and be of a simplex design which controls a single pump from a 3-float system or a duplex design which controls two pumps in an alternating lead\/lag cycle sequence from a 3 or 4-float system. The panel contains the required starting, control, \u0026amp; alarm circuits. Rated motor starters and circuit breakers are required for each pump. The 115 volt control circuit will have short circuit protection. The panel will have pump run pilot light(s) and pump alarm selector switches. The panel will be equipped with circuit(s) which automatically reverses the direction of the cutter blades. A seal leak indicator light is required as well as a thermal cut-out connection for 3 phase systems. A padlock hasp will be provided. High water conditions will be indicated by a visible light with polycarbonate cover. Numbered terminal strips are required. A wiring schematic and trouble shooting guide will be included with each panel. The panel will be UL listed and be labeled as such.\u003c\/p\u003e\n\n\u003ch3\u003eZoeller Control Panel 840 Simplex Features and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA 4X Outdoor Rating\u003c\/li\u003e\n\u003cli\u003eStarting, Control, and Alarm Circuits\u003c\/li\u003e\n\u003cli\u003eThermal Cut-Out Circuit (3 phase only)\u003c\/li\u003e\n\u003cli\u003eCapacitors and Motor Starting Relay On\u003c\/li\u003e\n\u003cli\u003eSingle Phase\u003c\/li\u003e\n\u003cli\u003eMotor Protective Switch (circuit breaker \/ adj overloads) and Rated Motor Contactor (3 Phase)\u003c\/li\u003e\n\u003cli\u003eAlternating Circuit (duplex)\u003c\/li\u003e\n\u003cli\u003eAutomatic Reversing Circuit\u003c\/li\u003e\n\u003cli\u003eHigh Water Alarm Light\u003c\/li\u003e\n\u003cli\u003eInternal Seal Leak Light\u003c\/li\u003e\n\u003cli\u003eHOA Switches and Pilot Light(s)\u003c\/li\u003e\n\u003cli\u003eTerminal Strips\u003c\/li\u003e\n\u003cli\u003ePadlock Hasp\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFLOAT SWITCHES NOT INCLUDED WITH THREE PHASE\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323196023101,"sku":"ZLR10-0396","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_2450763d-8c92-4a0f-a5e7-587a24bbee6a.jpg?v=1725383425"},{"product_id":"zoeller-10-1097-model-841-842-simplex-control-panel-single-directional-200-230v-3ph","title":"Zoeller 10-1097 Model 841 \u0026 842 Simplex Control Panel Single Directional 200\/230V 3PH","description":"\u003ch3\u003e\u003cimg width=\"299\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" name=\"mNkjyVLY-JcQXM:\" id=\"mNkjyVLY-JcQXM:\" height=\"93\" data-sz=\"f\" alt=\"zoeller-logo.jpg\"\u003e\u003c\/h3\u003e\n\u003ch3\u003eZoeller Simplex Control Panel Description\u003c\/h3\u003e\n\u003cp\u003eThe control panel can be housed in a NEMA 4X enclosure and be of a simplex design which controls a single pump from a 3-float system. For Models 841 \u0026amp; 842, Single Directional only. The panel contains the required starting, control, \u0026amp; alarm circuits. Rated motor starters and circuit breakers are required for each pump. The 115 volt control circuit will have short circuit protection. The panel will have pump run pilot light(s) and pump \u0026amp; alarm selector switches. The panel will be equipped with circuit(s) which automatically reverses the direction of the cutter blades. A seal leak indicator light is required as well as a thermal cut-out connection for 3 phase systems. A padlock hasp will be provided. High water conditions will be indicated by a visible light with polycarbonate cover. Numbered terminal strips are required. A wiring schematic and trouble shooting guide will be included with each panel. The panel will be UL listed and be labeled as such.\u003c\/p\u003e\n\u003ch3\u003eZoeller Simplex Control Panel Features and Benefits\u003c\/h3\u003e\n\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003e115-200-230 Volts\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Watertight Enclosure With Lockable Latch\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\u003c\/li\u003e\n\u003cli\u003eAlarm Horn Provides Audio Warning of Alarm Condition (83 to 85 decibel rating)\u003c\/li\u003e\n\u003cli\u003ePump Run Indicator Light\u003c\/li\u003e\n\u003cli\u003eHorn Silence and Alarm Test Toggle Switches\u003c\/li\u003e\n\u003cli\u003eHOA Switch\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003cli\u003eDry Auxiliary Contact (not available in plug-in panels)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e Three Phase Simplex Control Panel Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200, 230, 460, 575 Volts\u003c\/li\u003e\n\u003cli\u003eHand-Off-Toggle Switch\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Light\u003c\/li\u003e\n\u003cli\u003eAlarm Test and Silence Switches\u003c\/li\u003e\n\u003cli\u003eRed Alarm Beacon and Audible Alarm for a High Water Condition (83 to 85 decibel rating)\u003c\/li\u003e\n\u003cli\u003eMotor Protection Switch with Overload Protection\u003c\/li\u003e\n\u003cli\u003eMagnetic Starter\u003c\/li\u003e\n\u003cli\u003eNumbered Terminal Strip for Connecting Pumps and Variable Level Float Switches\u003c\/li\u003e\n\u003cli\u003eDry Auxiliary Contacts for Remote Alarm Devices\u003c\/li\u003e\n\u003cli\u003eThree Float Operation \u003cstrong\u003e(FLOAT SWITCHES NOT INCLUDED)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323199332669,"sku":"ZLR10-1097","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_67fa8ef4-c436-464c-9183-8b8ede0e1c6b.jpg?v=1725383478"},{"product_id":"zoeller-10-1094-model-841-842-simplex-control-panel-single-directional-460v-3ph","title":"Zoeller 10-1094 Model 841 \u0026 842 Simplex Control Panel Single Directional 460V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\n\u003ch3\u003eZoeller Simplex Control Panel Description\u003c\/h3\u003e\n\u003cp\u003e\n\tThe control panel can be housed in a NEMA 4X enclosure and be of a simplex design which controls a single pump from a 3-float system. For Models 841 \u0026amp; 842, Single Directional only. The panel contains the required starting, control, \u0026amp; alarm circuits. Rated motor starters and circuit  breakers are required for each pump. The 115 volt control circuit will have short circuit protection. The panel will have pump run pilot light(s) and pump \u0026amp; alarm selector switches. The panel will be equipped with circuit(s) which automatically reverses the direction of the cutter blades. A seal leak indicator light is required as well as a thermal cut-out\nconnection for 3 phase systems. A padlock hasp will be provided. High water\nconditions will be indicated by a visible light with polycarbonate cover. Numbered terminal strips are required. A wiring schematic and trouble shooting guide will be included with each panel. The panel will be UL listed and be labeled as such.\n\u003c\/p\u003e\n\u003ch3\u003eZoeller Simplex Control Panel Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e115-200-230 Volts\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Watertight Enclosure With Lockable Latch\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\u003c\/li\u003e\n\u003cli\u003eAlarm Horn Provides Audio Warning of Alarm Condition (83 to 85 decibel rating)\u003c\/li\u003e\n\u003cli\u003ePump Run Indicator Light\u003c\/li\u003e\n\u003cli\u003eHorn Silence and Alarm Test Toggle Switches\u003c\/li\u003e\n\u003cli\u003eHOA Switch\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003cli\u003eDry Auxiliary Contact (not available in plug-in panels)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\n  \u003cstrong\u003eThree Phase Simplex Control Panel Features:\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e200, 230, 460, 575 Volts\u003c\/li\u003e\n\u003cli\u003eHand-Off-Toggle Switch\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Light\u003c\/li\u003e\n\u003cli\u003eAlarm Test and Silence Switches\u003c\/li\u003e\n\u003cli\u003eRed Alarm Beacon and Audible Alarm for a High Water Condition (83 to 85 decibel rating)\u003c\/li\u003e\n\u003cli\u003eMotor Protection Switch with Overload Protection\u003c\/li\u003e\n\u003cli\u003eMagnetic Starter\u003c\/li\u003e\n\u003cli\u003eNumbered Terminal Strip for Connecting Pumps and Variable Level Float Switches\u003c\/li\u003e\n\u003cli\u003eDry Auxiliary Contacts for Remote Alarm Devices\u003c\/li\u003e\n\u003cli\u003eThree Float Operation \u003cstrong\u003e(FLOAT SWITCHES NOT INCLUDED)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323199856957,"sku":"ZLR10-1094","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_ffe9456a-6211-4b68-aed9-29957b7d92a0.jpg?v=1725383486"},{"product_id":"zoeller-10-1146-model-841-842-simplex-control-panel-single-directional-575v-3ph","title":"Zoeller 10-1146 Model 841 \u0026 842 Simplex Control Panel Single Directional 575V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\n\u003ch3\u003eZoeller Simplex Control Panel Description\u003c\/h3\u003e\n\u003cp\u003e\n\tThe control panel can be housed in a NEMA 4X enclosure and be of a simplex design which controls a single pump from a 3-float system. For Models 841 \u0026amp; 842, Single Directional only. The panel contains the required starting, control, \u0026amp; alarm circuits. Rated motor starters and circuit breakers are required for each pump. The 115 volt control circuit will have short circuit protection. The panel will have pump run pilot light(s) and pump \u0026amp; alarm selector switches. The panel will be equipped with circuit(s) which automatically reverses the direction of the cutter blades. A seal leak indicator light is required as well as a thermal cut-out\nconnection for 3 phase systems. A padlock hasp will be provided. High water\nconditions will be indicated by a visible light with polycarbonate cover.\nNumbered terminal strips are required. A wiring schematic and trouble\nshooting guide will be included with each panel. The panel will be UL listed and be labeled as such.\n\u003c\/p\u003e\n\u003ch3\u003eZoeller Simplex Control Panel Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e115-200-230 Volts\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Watertight Enclosure With Lockable Latch\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\u003c\/li\u003e\n\u003cli\u003eAlarm Horn Provides Audio Warning of Alarm Condition (83 to 85 decibel rating)\u003c\/li\u003e\n\u003cli\u003ePump Run Indicator Light\u003c\/li\u003e\n\u003cli\u003eHorn Silence and Alarm Test Toggle Switches\u003c\/li\u003e\n\u003cli\u003eHOA Switch\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003cli\u003eDry Auxiliary Contact (not available in plug-in panels)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eThree Phase Simplex Control Panel Features:\u003c\/strong\u003e\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e200, 230, 460, 575 Volts\u003c\/li\u003e\n\u003cli\u003eHand-Off-Toggle Switch\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Light\u003c\/li\u003e\n\u003cli\u003eAlarm Test and Silence Switches\u003c\/li\u003e\n\u003cli\u003eRed Alarm Beacon and Audible Alarm for a High Water Condition (83 to 85 decibel rating)\u003c\/li\u003e\n\u003cli\u003eMotor Protection Switch with Overload Protection\u003c\/li\u003e\n\u003cli\u003eMagnetic Starter\u003c\/li\u003e\n\u003cli\u003eNumbered Terminal Strip for Connecting Pumps and Variable Level Float Switches\u003c\/li\u003e\n\u003cli\u003eDry Auxiliary Contacts for Remote Alarm Devices\u003c\/li\u003e\n\u003cli\u003eThree Float Operation \u003cstrong\u003e(FLOAT SWITCHES NOT INCLUDED)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323200381245,"sku":"ZLR10-1146","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_cc03b86a-d6f0-4300-9e21-32529553b9f0.jpg?v=1725383493"},{"product_id":"zoeller-10-2710-intrinsically-safe-control-panel-simplex-auto-rev-200-230v-3ph","title":"Zoeller 10-2710 Intrinsically Safe Control Panel Simplex Auto Rev 200\/230V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2710 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5012-Zoeller-840-0066-Model-JX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-200V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 840-0066 Model JX840 \u0026quot;Shark\u0026quot; Reversing Grinder Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomatic\"\u003eZoeller 840-0066 Model JX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5013-Zoeller-840-0067-Model-FX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-230V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 840-0067 Model FX840 \u0026quot;Shark\u0026quot; Reversing Grinder Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\"\u003eZoeller 840-0067 Model FX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn With Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323205853501,"sku":"ZLR10-2710","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_acbfda45-7714-4d3a-aa2f-311f3ca7a3b2.jpg?v=1725383536"},{"product_id":"zoeller-10-2711-intrinsically-safe-control-panel-simplex-auto-rev-460v-3ph","title":"Zoeller 10-2711 Intrinsically Safe Control Panel Simplex Auto Rev 460V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2711 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5014-Zoeller-840-0068-Model-GX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-460V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 840-0068 Model GX840 \u0026quot;Shark\u0026quot; Reversing Grinder Pump Explosion Proof 2 HP 460V 3PH 20' Cord Nonautomatic\"\u003eZoeller 840-0068 Model GX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 460V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323206246717,"sku":"ZLR10-2711","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_bde06c27-3ed1-4f25-bfdc-48c6e451c636.jpg?v=1725383543"},{"product_id":"zoeller-10-2712-intrinsically-safe-control-panel-simplex-auto-rev-575v-3ph","title":"Zoeller 10-2712 Intrinsically Safe Control Panel Simplex Auto Rev 575V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2712 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5015-Zoeller-840-0069-Model-BAX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-575V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 840-0069 Model BAX840 \u0026quot;Shark\u0026quot; Reversing Grinder Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\"\u003eZoeller 840-0069 Model BAX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323206967613,"sku":"ZLR10-2712","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_b685a59b-a2e7-4e1d-88cd-a83bfba58c5c.jpg?v=1725383550"},{"product_id":"zoeller-10-1568-intrinsically-safe-control-panel-simplex-single-direction-200-230v-3ph","title":"Zoeller 10-1568 Intrinsically Safe Control Panel Simplex Single Direction 200\/230V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\n\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\n\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-1568 fits Model(s):\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"http:\/\/p\/5018-Zoeller-841-0019-Model-JX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-200V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 841-0019 Model JX841 \u0026quot;Shark\u0026quot; High Flow Grinder Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomatic\"\u003eZoeller 841-0019 Model JX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5019-Zoeller-841-0020-Model-FX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-230V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 841-0020 Model FX841 \u0026quot;Shark\u0026quot; High Flow Grinder Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\"\u003eZoeller 841-0020 Model FX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5024-Zoeller-842-0013-Model-JX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-200V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 842-0013 Model JX842 \u0026quot;Shark\u0026quot; High Head Grinder Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomatic\"\u003eZoeller 842-0013 Model JX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5025-Zoeller-842-0014-Model-FX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-230V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 842-0014 Model FX842 \u0026quot;Shark\u0026quot; High Head Grinder Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\"\u003eZoeller 842-0014 Model FX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323209785661,"sku":"ZLR10-1568","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_fefd174b-8435-498a-9989-f539ba0ec7aa.jpg?v=1725383592"},{"product_id":"zoeller-10-1560-intrinsically-safe-control-panel-simplex-single-direction-460v-3ph","title":"Zoeller 10-1560 Intrinsically Safe Control Panel Simplex Single Direction 460V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-1560 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5020-Zoeller-841-0021-Model-GX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-460V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 841-0021 Model GX841 \u0026quot;Shark\u0026quot; High Flow Grinder Pump Explosion Proof 2 HP 460V 3PH 20' Cord Nonautomatic\"\u003eZoeller 841-0021 Model GX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 460V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5026-Zoeller-842-0015-Model-GX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-460V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 842-0015 Model GX842 \u0026quot;Shark\u0026quot; High Head Grinder Pump Explosion Proof 2 HP 460V 3PH 20' Cord Nonautomatic\"\u003eZoeller 842-0015 Model GX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 460V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Endicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323210932541,"sku":"ZLR10-1560","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_fcc3d19a-dc89-459e-91f2-44da659fd048.jpg?v=1725383599"},{"product_id":"zoeller-10-2720-intrinsically-safe-control-panel-simplex-single-direction-575v-3ph","title":"Zoeller 10-2720 Intrinsically Safe Control Panel Simplex Single Direction 575V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\n\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\n\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2720 fits Model(s):\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5021-Zoeller-841-0022-Model-BAX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-575V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\"\u003eZoeller 841-0022 Model BAX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5027-Zoeller-842-0016-Model-BAX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-575V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 842-0016 Model BAX842 \u0026quot;Shark\u0026quot; High Head Grinder Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\"\u003eZoeller 842-0016 Model BAX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323211391293,"sku":"ZLR10-2720","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_9e6a536a-cf2a-414d-8a7a-2198f03963f0.jpg?v=1725383605"},{"product_id":"zoeller-10-0353-simplex-reversing-control-box-200-230-460v-3ph-automatic","title":"Zoeller 10-0353 Simplex Reversing Control Box 200\/230\/460V 3PH Automatic","description":"\u003ch3\u003e\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\u003c\/h3\u003e\n\u003ch3\u003eZoeller Model 840 Reversing Boxes Description\u003c\/h3\u003e\n\u003cp\u003eReversing boxes will not control pumps. They contain reversing mechanisms and capacitors (1 Ph units) only. For duplex applications use two simplex reversing boxes.\u003c\/p\u003e\n\u003cp\u003eZoeller Simplex Reversing Control Box 10-0353 fits Model(s:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/rcworst.com\/products\/zoeller-840-0006-model-f840-shark-auto-reversing-grinder-pump-2-hp-230v-3ph-20-cord-nonautomatic\" target=\"_blank\" title=\"Zoeller 840-0006 Model F840 \u0026quot;Shark\u0026quot; Auto Reversing Grinder Pump 2 HP 230V 3PH 20' Cord Automatic\" rel=\"noopener\"\u003eZoeller 840-0006 Model F840 \"Shark\" Auto Reversing Grinder Pump 2 HP 230V 3PH 20' Cord Automatic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/rcworst.com\/products\/zoeller-840-0007-model-j840-shark-auto-reversing-grinder-pump-2-hp-200v-3ph-20-cord-nonautomatic?_pos=1\u0026amp;_psq=840-0007\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\" title=\"Zoeller 840-0007 Model J840 \u0026quot;Shark\u0026quot; Auto Reversing Grinder Pump 2 HP 200V 3PH 20' Cord Automatic\" rel=\"noopener\"\u003eZoeller 840-0007 Model J840 \"Shark\" Auto Reversing Grinder Pump 2 HP 200V 3PH 20' Cord Automatic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/rcworst.com\/products\/zoeller-840-0008-model-g840-shark-auto-reversing-grinder-pump-2-hp-460v-3ph-20-cord-nonautomatic?_pos=1\u0026amp;_psq=840-0008\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\" title=\"Zoeller 840-0008 Model G840 \u0026quot;Shark\u0026quot; Auto Reversing Grinder Pump 2 HP 460V 3PH 20' Cord Automati\" rel=\"noopener\"\u003eZoeller 840-0008 Model G840 \"Shark\" Auto Reversing Grinder Pump 2 HP 460V 3PH 20' Cord Automatic\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZoeller Model 840 Reversing Boxes Features and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA4X Thermoplastic Enclosure\u003c\/li\u003e\n\u003cli\u003eUL Labeled\u003c\/li\u003e\n\u003cli\u003eAutomatic Reversing Circuitry\u003c\/li\u003e\n\u003cli\u003eSimplex or Duplex Configuration\u003c\/li\u003e\n\u003cli\u003eControl Side Fuses\u003c\/li\u003e\n\u003cli\u003eControl On\/Off Switch\u003c\/li\u003e\n\u003cli\u003eLockable Hasp\u003c\/li\u003e\n\u003cli\u003eHOA Switch(es)\u003c\/li\u003e\n\u003cli\u003eI.E.C. Rated Motor Contactor(s)\u003c\/li\u003e\n\u003cli\u003e120 Volt Control Circuit\u003c\/li\u003e\n\u003cli\u003ePump Circuit Breaker(s) or Motor Overload\u003c\/li\u003e\n\u003cli\u003eProtection w\/ Disconnect (3 Phase)\u003c\/li\u003e\n\u003cli\u003eExternal High Water Alarm Light\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indication Light\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Light(s)\u003c\/li\u003e\n\u003cli\u003eCapacitors and Start Relay (1 Phase)\u003c\/li\u003e\n\u003cli\u003eAlternating Circuit Board (Duplex)\u003c\/li\u003e\n\u003cli\u003eFloat Status Indicator Lights\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323213947197,"sku":"ZLR10-0353","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0352_reversing_box_w_d69fbab9-59da-4b4f-b6b0-5ab634e9099c.jpg?v=1725383648"},{"product_id":"zoeller-10-0361-simplex-reversing-control-box-200-230v-3ph-manual","title":"Zoeller 10-0361 Simplex Reversing Control Box 200\/230V 3PH Manual","description":"\u003ch3\u003e\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\u003c\/h3\u003e\n\u003ch3\u003eZoeller Model 840 Reversing Boxes Description\u003c\/h3\u003e\n\u003cp\u003eReversing boxes will not control pumps. They contain reversing mechanisms and capacitors (1 Ph units) only. For duplex applications use two simplex reversing boxes.\u003c\/p\u003e\n\u003cp\u003eZoeller Simplex Reversing Control Box 10-0361 fits Model(s):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/rcworst.com\/products\/zoeller-840-0004-model-e840-shark-auto-reversing-grinder-pump-2-0-hp-230v-1ph-20-cord-nonautomatic?_pos=1\u0026amp;_psq=840-0004\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\" title=\"Zoeller 840-0006 Model F840 \u0026quot;Shark\u0026quot; Auto Reversing Grinder Pump 2 HP 230V 3PH 20' Cord Automatic\" rel=\"noopener\"\u003eZoeller 840-0004 Model E840 \"Shark\" Auto Reversing Grinder Pump 2 HP 230V 1PH 20' Cord Automatic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/rcworst.com\/products\/zoeller-840-0007-model-j840-shark-auto-reversing-grinder-pump-2-hp-200v-3ph-20-cord-nonautomatic?_pos=1\u0026amp;_psq=840-0007\u0026amp;_ss=e\u0026amp;_v=1.0\" target=\"_blank\" title=\"Zoeller 840-0007 Model J840 \u0026quot;Shark\u0026quot; Auto Reversing Grinder Pump 2 HP 200V 3PH 20' Cord Automatic\" rel=\"noopener\"\u003eZoeller 840-0007 Model J840 \"Shark\" Auto Reversing Grinder Pump 2 HP 200V 3PH 20' Cord Automatic\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZoeller Model 840 Reversing Boxes Features and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA4X Thermoplastic Enclosure\u003c\/li\u003e\n\u003cli\u003eUL Labeled\u003c\/li\u003e\n\u003cli\u003eAutomatic Reversing Circuitry\u003c\/li\u003e\n\u003cli\u003eSimplex or Duplex Configuration\u003c\/li\u003e\n\u003cli\u003eControl Side Fuses\u003c\/li\u003e\n\u003cli\u003eControl On\/Off Switch\u003c\/li\u003e\n\u003cli\u003eLockable Hasp\u003c\/li\u003e\n\u003cli\u003eHOA Switch(es)\u003c\/li\u003e\n\u003cli\u003eI.E.C. Rated Motor Contactor(s)\u003c\/li\u003e\n\u003cli\u003e120 Volt Control Circuit\u003c\/li\u003e\n\u003cli\u003ePump Circuit Breaker(s) or Motor Overload\u003c\/li\u003e\n\u003cli\u003eProtection w\/ Disconnect (3 Phase)\u003c\/li\u003e\n\u003cli\u003eExternal High Water Alarm Light\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indication Light\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Light(s)\u003c\/li\u003e\n\u003cli\u003eCapacitors and Start Relay (1 Phase)\u003c\/li\u003e\n\u003cli\u003eAlternating Circuit Board (Duplex)\u003c\/li\u003e\n\u003cli\u003eFloat Status Indicator Lights\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323214733629,"sku":"ZLR10-0361","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0352_reversing_box_w_51a5e6f1-a258-48f8-87e2-fff297485da3.jpg?v=1725383667"},{"product_id":"sje-rhombus-model-ifs5-3-phase-208-240-460-600v-simplex-control-panel","title":"SJE-Rhombus Model IFS5 3-Phase 208\/240\/460\/600V Simplex Control Panel","description":"\u003cp\u003e\n\u003cimg alt=\"sjerhombuslogo6002018.jpg\" data-image=\"n74xi8cu9ab6\" height=\"97\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/sjerhombuslogo6002018.jpg\" title=\"sjerhombuslogo6002018.jpg\" width=\"600\"\u003e\n\u003c\/p\u003e\n\u003ch3\u003eINSTALLER FRIENDLY SERIES® - IFS Three Phase Simplex Panel Description\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInstaller Friendly Series® control panels utilize circuit board technology for advanced pump control and system monitoring.\u003c\/strong\u003e\n\u003c\/p\u003e\n\u003cp\u003eThe Installer Friendly Series® Three Phase Simplex Demand\/TD control panel is designed to control one 208\/240\/480V three phase pump in water and sewage installations.\n\u003c\/p\u003e\n\u003cp\u003eThe IFS panel features a simple, easy-to-use color LCD interface located on the inner door for programming and system monitoring. The panel configuration can be easily converted in the field to either a timed dose or demand dose through the LCD interface.\n\u003c\/p\u003e\n\u003cp\u003eThe panel can easily be changed in the field to utilize floats, Sub-X™ LT Transmitter or the C-Level™ Sensor for continuous monitoring. The Sub-X™ LT Transmitter and the C-Level™ Sensor sense the level in the tank and sends a signal to the panel. Pump activation levels can be adjusted by using the LCD interface.\u003c\/p\u003e\n\u003ch3\u003eSJE-Rhombus Model IFS Three Phase Simplex Panel Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cu\u003e\u003cstrong\u003eLCD Interface Features:\u003c\/strong\u003e\u003c\/u\u003e\n\u003cli\u003eFull Color Graphics and Menu Navigation Encoder for Easy Setup\u003c\/li\u003e\n\u003cli\u003eTouch Safe Housing\u003c\/li\u003e\n\u003cli\u003ePump Hand\/Off\/Auto Control Selectable via Menu Navigation\u003c\/li\u003e\n\u003cli\u003eSub-X™ LT Transmitter, C-Level™ Sensor or Float Operation Selectable\u003c\/li\u003e\n\u003cli\u003eDemand or Timed Dose Operation Selectable via Menu Navigation\u003c\/li\u003e\n\u003cli\u003eTank Level Indication and Setpoint Monitoring At-A-Glance\u003c\/li\u003e\n\u003cli\u003eLead pump is Easily Identified by a Graphic Ring Around the Current Lead Pump Regardless of Control Mode (timed dose or demand)\u003c\/li\u003e\n\u003cli\u003eDisplays Remaining Time in Timed Dose Mode\u003c\/li\u003e\n\u003cli\u003eRJ45 Communication Connector\u003c\/li\u003e\n\u003cli\u003eFlashing Function for Alarm Beacon and Horn (configurable)\u003c\/li\u003e\n\u003cli\u003eManual Alarm Reset (configurable)\u003c\/li\u003e\n\u003cli\u003eThermal Cutout and Seal Failure Module (optional)\u003c\/li\u003e\n\u003cli\u003eUL\/cUL Listed\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n  \u003cul\u003e\n\u003cli\u003eFive-Year Limited Warranty on Panel\u003c\/li\u003e\n\u003cli\u003eTwo-Year Limited Warranty on C-Level™ Sensor and Sub-X™ LT Transmitter\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"SJE Rhombus","offers":[{"title":"Default Title","offer_id":49327781445949,"sku":"CP-SJEIFS5","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/sjeifs5panel-001_wbg.jpg?v=1774565349"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/collections\/10_0352_reversing_box_w_21c6e480-56c4-40cd-a16d-7161eb8d4636.jpg?v=1727893174","url":"https:\/\/rcworst.com\/collections\/seal-fail-circuit-3.oembed","provider":"R.C. Worst \u0026 Company Inc","version":"1.0","type":"link"}