{"title":"Intrinsically Safe","description":"","products":[{"product_id":"zoeller-10-2709-intrinsically-safe-control-panel-simplex-auto-rev-200-230v-1ph","title":"Zoeller 10-2709 Intrinsically Safe Control Panel Simplex Auto Rev 200\/230V 1PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2709 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5010-Zoeller-840-0064-Model-EX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-230V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\"\u003eZoeller 840-0064 Model EX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5011-Zoeller-840-0065-Model-IX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-200V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\"\u003eZoeller 840-0065 Model IX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 200V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323205263677,"sku":"ZLR10-2709","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w.jpg?v=1725383528"},{"product_id":"zoeller-10-2717-intrinsically-safe-control-panel-simplex-single-direction-200-230v-1ph","title":"Zoeller 10-2717 Intrinsically Safe Control Panel Simplex Single Direction 200\/230V 1PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\n\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\n\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2717 fits Model(s):\n\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5016-Zoeller-841-0017-Model-EX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-230V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 841-0017 Model EX841 \u0026quot;Shark\u0026quot; High Flow Grinder Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\"\u003eZoeller 841-0017 Model EX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5017-Zoeller-841-0018-Model-IX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-200V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\"\u003eZoeller 841-0018 Model IX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 200V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5022-Zoeller-842-0011-Model-EX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-230V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\"\u003eZoeller 842-0011 Model EX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5023-Zoeller-842-0012-Model-IX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-200V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\"\u003eZoeller 842-0012 Model IX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 200V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn With Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323209326909,"sku":"ZLR10-2717","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_dfa5f76a-6b5f-4a05-b672-9777bb7b51ee.jpg?v=1725383585"},{"product_id":"orenco-mvp-ssf-series-dual-independent-pump-control-panel","title":"Orenco MVP SSF Series Dual Independent Pump Control Panel","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/orencocontrilsheadern.jpg\" data-image=\"e794dsmvq4hb\"\u003e\u003c\/p\u003e\n\u003cp\u003eOrenco's MVP SSF control panels are digital, programmable panels used to control two pumps when pumping from point \"A\" (first pump) to point \"B,\" and then from point \"B\" (second pump) to point \"C,\" and to provide alarm functions in systems where controls for motors in series are required. Interlocked controls prevent the first (upstream) pump from running if a high level alarm condition occurs in the down-stream pump.\u003c\/p\u003e\n\u003cp\u003eMVP SSF Control Panels include easy-to-use, programmable logic units that incorporate multiple timing and logic functions, including multiple timer intervals to adjust for changing flow conditions.\u003c\/p\u003e\n\u003cp\u003eMVP SSF panels offer several standard functions, including elapsed time meters, counters, digital indication of float switch status, different alarm\/light signals for varying alarm conditions, and the ability to use one type of float switch for all functions. In dual-mode MVP SSF control panels, the downstream pump can be configured in the field for demand dose or time-dose applications.\u003c\/p\u003e\n\u003ch3\u003eOrenco MVP SSF Series Simplex Control Panel Typical Application\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential and Light Commercial Sump, Septic Tank Effluent, and Raw Sewage Pumping Applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eAdditional Features:\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eHT - Heater\u003c\/li\u003e\n\u003cli\u003ePTRO - Programmable Timer, Redundant Off, Recirc Pump\u003c\/li\u003e\n\u003cli\u003eDM - Dual-Mode\u003c\/li\u003e\n\u003cli\u003eRO - Redundant Off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Orenco Systems, Inc.","offers":[{"title":"Default Title","offer_id":49325360873789,"sku":"ONCMVPSSF1HTPTRO\/DMRO","price":1815.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/oncsseriespanel_001_wbg_93aacbf8-01ae-4f49-a27b-8a4a05df6208.jpg?v=1725428847"},{"product_id":"sje-rhombus-model-114-simplex-single-phase-pump-control-intrinsically-safe","title":"SJE-Rhombus Model 114 Simplex Single Phase Pump Control Intrinsically Safe","description":"\u003cp\u003e\n\u003cimg alt=\"sjerhombuslogo6002018.jpg\" data-image=\"8l1lxom6fmgu\" height=\"97\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/sjerhombuslogo6002018.jpg\" title=\"sjerhombuslogo6002018.jpg\" width=\"600\"\u003e\n\u003c\/p\u003e\n\u003ch3\u003eSJE-Rhombus Model 114 - Single Phase Simplex Pump Control Panel Description\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSingle Phase Simplex Pump Control with Intrinsically Safe Circuits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\n\tThe Model 114 control panel is designed for applications requiring intrinsically safe float circuits or other circuit extensions. This panel will control one 120,208, or 240 VAC single phase pump. Two control switches activate a magnetic motor contactor to turn the pump on and off. If an alarm condition occurs, and additional alarm switch activates the audio\/visual alarm system. Common applications include pump chambers, lift stations or other installations classified as hazardous locations requiring intrinsically safe circuits.\n\u003c\/p\u003e\n\u003cp\u003e\n\tThe Model 114 control panel features built in pump failure and float out of sequence detection. In addition, there are three user selectable field programmable options: alarm steady state or flashing; alarm auto reset or manual reset; and optional seal failure alarm beacon plus horn activation.\n\u003c\/p\u003e\n\u003cp\u003eSimplex controller features include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTouch Safe Circuit Board Housing and Low Voltage 24 VDC Float Circuits\u003c\/li\u003e\n\u003cli\u003eAlarm (field programmable to flash)\u003c\/li\u003e\n\u003cli\u003eAlarm Automatic Reset (field programmable to manual alarm reset) \u003c\/li\u003e\n\u003cli\u003eFloat Out-of-Sequence Detection\u003c\/li\u003e\n\u003cli\u003ePump Contactor Failure Detection\u003c\/li\u003e\n\u003cli\u003eController Protected by Three Auto Resettable Fuses ( control, alarm, and pump 1)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e NOTE: SJE Rhombus Recommends Separate Pump and Control\/Alarm Power Sources \u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003eSJE-Rhombus Model 114 - Single Phase Simplex Pump Control Panel w\/Intrinsically Safe Circuits Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA 4X (indoor\/outdoor) Enclosure\u003c\/li\u003e\n\u003cli\u003eRed Alarm Beacon Provides 360º Visual Check of Alarm Condition\u003c\/li\u003e\n\u003cli\u003eAlarm Horn Provides Audio Warning of Alarm Condition\u003c\/li\u003e\n\u003cli\u003eExterior Alarm Test\/Normal\/Silence Switch Allows Horn and Light to be Tested and Horn to be Silenced in an Alarm Condition; Alarm Automatically Resets Once Alarm Condition is Cleared\u003c\/li\u003e\n\u003cli\u003eHorn Silence Relay\u003c\/li\u003e\n\u003cli\u003eIntrinsically Safe Module Limits the Amount of Energy to Switches Preventing Ignition of Flammable Gases\u003c\/li\u003e\n\u003cli\u003eIntrinsically Safe Partition Isolates the Intrinsically Safe Wiring\u003c\/li\u003e\n\u003cli\u003eIEC Motor Contactor Controls Pump by Switching Electrical Lines\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Auto (HOA) Switch for Manual Pump Control\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Indicator Light\u003c\/li\u003e\n\u003cli\u003eAlarm and Control Fuses\/Indicators\u003c\/li\u003e\n\u003cli\u003eInput Power Terminal Block\u003c\/li\u003e\n\u003cli\u003eGround Lugs\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker (optional) Provides Pump Disconnect and Branch Circuit Protection\u003c\/li\u003e\n\u003cli\u003eOverload Relay (optional) Provides Thermal Overload Protection for Pump\u003c\/li\u003e\n\u003cli\u003eUL\/cUL Listed\u003c\/li\u003e\n\u003cli\u003eFive-Year Limited Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIndustrial Panel is UL Listed Relating to Hazardous Locations with Intrinsically Safe Circuit Extensions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModel 114 Control Panel Cannot Be Returned\u003c\/strong\u003e\u003c\/p\u003e","brand":"SJE Rhombus","offers":[{"title":"Default Title","offer_id":49327440560445,"sku":"CP-SJE114","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/sjepanel11423_001_wbg.jpg?v=1725450870"},{"product_id":"orenco-mvp-s-simplex-series-dual-voltage-custom-control-panel","title":"Orenco MVP-S Simplex Series Dual Voltage Custom Control Panel","description":"\u003cp\u003e\u003cimg data-image=\"jgbmng1ad3w9\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/orencocontrilsheadern.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003eMVP simplex control panels are digital, programmable panels used to control single pumps and provide alarm functions in onsite septic systems and effluent pumping systems. They include easy-to-use, programmable logic units that incorporate multiple built-in timing and logic functions, including multiple timer intervals to adjust for changing flow conditions. MVP panels offer several standard functions, including elapsed time meters, counters, digital indication of float switch status, different alarm\/light signals for varying alarm conditions, and the ability to use one type of float switch for all functions. Dual-mode MVP simplex control panels can be configured in the field for demand-dose or timed-dose applications.\u003c\/p\u003e\n\u003ch3\u003eOrenco MVP Series Simplex Control Panel Typical Application\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential and Light Commercial Sump, Septic Tank Effluent, and Raw Sewage Pumping Applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrenco MVP Series Control Panel Features and Benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e120-VAC Controls Circuit Breaker\u003c\/li\u003e\n\u003cli\u003e120- or 120\/240-VAC Pump Circuit Breaker\u003c\/li\u003e\n\u003cli\u003eMotor-Start Contactors for Pump Circuits\u003c\/li\u003e\n\u003cli\u003eAutomatic\/Off\/Manual (Auto\/Off\/Man) Toggle Switch\u003c\/li\u003e\n\u003cli\u003e7\/8-in (22-mm) Red Visible Alarm\u003c\/li\u003e\n\u003cli\u003e95 dB Audible Alarm\u003c\/li\u003e\n\u003cli\u003eAutomatic Alarm Silence Reset\u003c\/li\u003e\n\u003cli\u003eBuilt-In Elapsed Time Meter\u003c\/li\u003e\n\u003cli\u003eBuilt-In Event Counter\u003c\/li\u003e\n\u003cli\u003eType 4X(IP 66) Rated Enclosure\u003c\/li\u003e\n\u003cli\u003eMechanical or Mercury Float Switches Ordered Separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrenco MVP Series Simplex Control Panel Optional Features\u003c\/h3\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eHT\u003c\/strong\u003e - Heater - Anti-condensation heater; self-adjusting: radiates additional wattage as temperature drops\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003ePRL\u003c\/strong\u003e - Pump Run Light - 7\/8\" green lens. NEMA 4, 1 Watt bulb, 120 VAC\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eSA\u003c\/strong\u003e - Surge Arrestor - Status light on unit; protects incoming power supply from electrical surges\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eIR\u003c\/strong\u003e - Intrinsically Safe Control Relays - Listed per UL 698A, for Class 1 Div. 1, groups A, B, C, D hazardous locations (requires larger enclosure)\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003ePT\u003c\/strong\u003e - Programmable Timer - multiple built-in timing and logic functions\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eETM\u003c\/strong\u003e - Elapsed Time Meter - Tracks and compiles total pump run time\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eCT\u003c\/strong\u003e - Event Counter - Tracks and compiles pump events\u003c\/p\u003e\n\u003chr\u003e\n\u003cp\u003e\u003cstrong\u003eRO\u003c\/strong\u003e - Redundant Off - DIN rail mount; provides a secondary off; sounds alarm upon low level condition\u003c\/p\u003e\n\u003chr\u003e","brand":"Orenco Systems, Inc.","offers":[{"title":"Default Title","offer_id":49327493480765,"sku":"CP-ONCMVPS2","price":949.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/oncmvpseries_001_wbg.jpg?v=1725451922"},{"product_id":"orenco-mvps1-s2dm-mf3p-simplex-dual-mode-control-panel-kit-with-liquid-level-switches-120-240v","title":"Orenco MVPS1\/S2DM MF3P Simplex Dual Mode Control Panel Kit with Liquid Level Switches 120\/240V","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/orencocontrilsheadern.jpg\"\u003e\u003c\/p\u003e\n\u003cp\u003eThe MVP-S1\/2DM (4-in-1) control panel is ideal for single-pump systems that might otherwise require several different types of panels. The controls circuit operates on 120 V power, the pump circuit is dual-rated for 120 V or 240 V power. In addition, the panel can be configured at the shop or in the field for timed-or demand-dosing applications. All MVPs include an easy-to-use, programmable logic unit that incorporates many timing and logic functions, such as multiple timing intervals to adjust for changing flow conditions and a built-in elapsed time meter and counter.\u003c\/p\u003e\n\u003ch3\u003eOrenco MVPS1\/S2DM Typical Application\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential and Light Commercial Sump, Septic Tank Effluent, and Raw Sewage Pumping Applications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Orenco Systems, Inc.","offers":[{"title":"Default Title","offer_id":49328945856829,"sku":"ONCMVPS1\/2DM-MF3PKIT","price":1144.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/orencomvps1s2panelfrontmfp_w.jpg?v=1725481838"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/collections\/10_0125_w_c61fb68f-021b-49ed-8330-26b64b9ad04b.jpg?v=1727897838","url":"https:\/\/rcworst.com\/collections\/intrinsically-safe-5.oembed","provider":"R.C. Worst \u0026 Company Inc","version":"1.0","type":"link"}