{"title":"Intrinsically Safe","description":"","products":[{"product_id":"zoeller-10-1125-model-841-842-duplex-control-panel-single-directional-200-230v-3ph","title":"Zoeller 10-1125 Model 841 \u0026 842 Duplex Control Panel Single Directional 200\/230V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\n\u003ch3\u003eZoeller Duplex Control Panel Description\u003c\/h3\u003e\n\u003cp\u003e\nThe control panel can be housed in a NEMA 4X enclosure and be of a duplex\ndesign which controls two pumps in an alternating lead\/lag cycle sequence\nfrom a 3 or 4-float system. For Models 841 \u0026amp; 842, Single Directional\nonly. The panel contains the required starting, control, \u0026amp; alarm\ncircuits. Rated motor starters and circuit breakers are required for each\npump. The 115 volt control circuit will have short circuit protection. The\npanel will have pump run pilot light(s) and pump \u0026amp; alarm selector\nswitches. The panel will be equipped with circuit(s) which automatically\nreverses the direction of the cutter blades. A seal leak indicator light is\nrequired as well as a thermal cut-out connection for 3 phase systems. A\npadlock hasp will be provided. High water conditions will be indicated by a\nvisible light with polycarbonate cover. Numbered terminal strips are\nrequired. A wiring schematic and trouble shooting guide will be included\nwith each panel. The panel will be UL listed and be labeled as such.\n\u003c\/p\u003e\n\u003ch3\u003eZoeller Duplex Control Panel Features and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eHand Off Auto Toggle Switch for Each Pump\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\u003c\/li\u003e\n\u003cli\u003eAlarm Test and Silence Switches\u003c\/li\u003e\n\u003cli\u003eRed Pilot Light (NEMA 1 only) and Audible Alarm with 83 to 85 Decibel Rating for a High Water Condition\u003c\/li\u003e\n\u003cli\u003eRed Alarm Beacon Included With NEMA 4X Enclosure\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\u003c\/li\u003e\n\u003cli\u003eHigh Water Alarm\u003c\/li\u003e\n\u003cli\u003eOn Three Phase – Motor Protective Switch With Overload Protection\u003c\/li\u003e\n\u003cli\u003eMagnetic Starter for Each Pump\u003c\/li\u003e\n\u003cli\u003eAlternating Mechanism\u003c\/li\u003e\n\u003cli\u003eNumbered Terminal Strip for Connecting Pumps and Variable Level Float Switches\u003c\/li\u003e\n\u003cli\u003eNEMA 1, General Purpose or NEMA 4X, Watertight Enclosures Available\u003c\/li\u003e\n\u003cli\u003eIntegral Auxiliary Terminal Board Connections (dry contact) for Remote Alarm Devices\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Level Float Switch Control Operation\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy Field Maintenance and Repair\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFLOAT SWITCHES NOT INCLUDED WITH THREE PHASE\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323202543933,"sku":"ZLR10-1125","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_49f83800-c3f4-4c5e-afb2-e156b493f053.jpg?v=1725383507"},{"product_id":"zoeller-10-1168-model-841-842-duplex-control-panel-single-directional-575v-3ph","title":"Zoeller 10-1168 Model 841 \u0026 842 Duplex Control Panel Single Directional 575V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\n\u003ch3\u003eZoeller Duplex Control Panel Description\u003c\/h3\u003e\n\u003cp\u003e\nThe control panel can be housed in a NEMA 4X enclosure and be of a duplex\ndesign which controls two pumps in an alternating lead\/lag cycle sequence\nfrom a 3 or 4-float system. For Models 841 \u0026amp; 842, Single Directional\nonly. The panel contains the required starting, control, \u0026amp; alarm\ncircuits. Rated motor starters and circuit breakers are required for each\npump. The 115 volt control circuit will have short circuit protection. The\npanel will have pump run pilot light(s) and pump \u0026amp; alarm selector\nswitches. The panel will be equipped with circuit(s) which automatically\nreverses the direction of the cutter blades. A seal leak indicator light is\nrequired as well as a thermal cut-out connection for 3 phase systems. A\npadlock hasp will be provided. High water conditions will be indicated by a\nvisible light with polycarbonate cover. Numbered terminal strips are\nrequired. A wiring schematic and trouble shooting guide will be included\nwith each panel. The panel will be UL listed and be labeled as such.\n\u003c\/p\u003e\n\u003ch3\u003eZoeller Duplex Control Panel Features and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eHand Off Auto Toggle Switch for Each Pump\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\u003c\/li\u003e\n\u003cli\u003eAlarm Test and Silence Switches\u003c\/li\u003e\n\u003cli\u003eRed Pilot Light (NEMA 1 only) and Audible Alarm with 83 to 85 Decibel Rating for a High Water Condition\u003c\/li\u003e\n\u003cli\u003eRed Alarm Beacon Included With NEMA 4X Enclosure\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\u003c\/li\u003e\n\u003cli\u003eHigh Water Alarm\u003c\/li\u003e\n\u003cli\u003eOn Three Phase – Motor Protective Switch With Overload Protection\u003c\/li\u003e\n\u003cli\u003eMagnetic Starter for Each Pump\u003c\/li\u003e\n\u003cli\u003eAlternating Mechanism\u003c\/li\u003e\n\u003cli\u003eNumbered Terminal Strip for Connecting Pumps and Variable Level Float Switches\u003c\/li\u003e\n\u003cli\u003eNEMA 1, General Purpose or NEMA 4X, Watertight Enclosures Available\u003c\/li\u003e\n\u003cli\u003eIntegral Auxiliary Terminal Board Connections (dry contact) for Remote Alarm Devices\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Level Float Switch Control Operation\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy Field Maintenance and Repair\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFLOAT SWITCHES NOT INCLUDED WITH THREE PHASE\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323204772157,"sku":"ZLR10-1168","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_7d2e79e4-7038-41cc-8a86-ed8e6628369f.jpg?v=1725383521"},{"product_id":"zoeller-10-2714-intrinsically-safe-control-panel-duplex-auto-200-230v-3ph","title":"Zoeller 10-2714 Intrinsically Safe Control Panel Duplex Auto 200\/230V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2714 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5012-Zoeller-840-0066-Model-JX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-200V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 840-0066 Model JX840 \u0026quot;Shark\u0026quot; Reversing Grinder Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomatic\"\u003eZoeller 840-0066 Model JX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5013-Zoeller-840-0067-Model-FX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-230V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 840-0067 Model FX840 \u0026quot;Shark\u0026quot; Reversing Grinder Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\"\u003eZoeller 840-0067 Model FX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic motor contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Endicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323207917885,"sku":"ZLR10-2714","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_ba2177de-e578-44d1-bd76-c68e4919305a.jpg?v=1725383565"},{"product_id":"zoeller-10-2715-intrinsically-safe-control-panel-duplex-auto-rev-460v-3ph","title":"Zoeller 10-2715 Intrinsically Safe Control Panel Duplex Auto Rev 460V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2715 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5014-Zoeller-840-0068-Model-GX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-460V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 840-0068 Model GX840 \u0026quot;Shark\u0026quot; Reversing Grinder Pump Explosion Proof 2 HP 460V 3PH 20' Cord Nonautomatic\"\u003eZoeller 840-0068 Model GX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 460V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn With Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323208409405,"sku":"ZLR10-2715","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_0f2ed66d-f14c-4bf3-b3eb-debc5cdf2629.jpg?v=1725383571"},{"product_id":"zoeller-10-2716-intrinsically-safe-control-panel-duplex-auto-rev-575v-3ph","title":"Zoeller 10-2716 Intrinsically Safe Control Panel Duplex Auto Rev 575V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2716 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5015-Zoeller-840-0069-Model-BAX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-575V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 840-0069 Model BAX840 \u0026quot;Shark\u0026quot; Reversing Grinder Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\"\u003eZoeller 840-0069 Model BAX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323208868157,"sku":"ZLR10-2716","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_bcfe6fed-5da0-4ce3-8bd9-897466ef020a.jpg?v=1725383578"},{"product_id":"zoeller-10-1596-intrinsically-safe-control-panel-duplex-single-direction-200-230v-3ph","title":"Zoeller 10-1596 Intrinsically Safe Control Panel Duplex Single Direction 200\/230V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-1596 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5018-Zoeller-841-0019-Model-JX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-200V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 841-0019 Model JX841 \u0026quot;Shark\u0026quot; High Flow Grinder Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomati\"\u003eZoeller 841-0019 Model JX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomati\u003c\/a\u003e\u003ca href=\"http:\/\/rcworst.com\/zoeller-841-0019-model-jx841-shark-high-flow-grinder-pump-explosion-proof-2-hp-200v-3ph-20-cord-nonautomatic\/\"\u003ec\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5024-Zoeller-842-0013-Model-JX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-200V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 842-0013 Model JX842 \u0026quot;Shark\u0026quot; High Head Grinder Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomati\"\u003eZoeller 842-0013 Model JX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 200V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5019-Zoeller-841-0020-Model-FX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-230V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 841-0020 Model FX841 \u0026quot;Shark\u0026quot; High Flow Grinder Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\"\u003eZoeller 841-0020 Model FX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5025-Zoeller-842-0014-Model-FX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-230V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 842-0014 Model FX842 \u0026quot;Shark\u0026quot; High Head Grinder Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\"\u003eZoeller 842-0014 Model FX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 230V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323212046653,"sku":"ZLR10-1596","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_5e893e23-2271-4e86-b86c-21d895e1f6a8.jpg?v=1725383619"},{"product_id":"zoeller-10-2724-intrinsically-safe-control-panel-duplex-single-direction-575v-3ph","title":"Zoeller 10-2724 Intrinsically Safe Control Panel Duplex Single Direction 575V 3PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2724 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5021-Zoeller-841-0022-Model-BAX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-575V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 841-0022 Model BAX841 \u0026quot;Shark\u0026quot; High Flow Grinder Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\"\u003eZoeller 841-0022 Model BAX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5027-Zoeller-842-0016-Model-BAX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-575V-3PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 842-0016 Model BAX842 \u0026quot;Shark\u0026quot; High Head Grinder Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\"\u003eZoeller 842-0016 Model BAX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 575V 3PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn With Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323213095229,"sku":"ZLR10-2724","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_fab00751-2096-4007-97dd-aed45fc065e8.jpg?v=1725383633"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/collections\/10_0393_w_5dd0873f-1e2f-4590-9ccf-6256ec1bb266.jpg?v=1727893148","url":"https:\/\/rcworst.com\/collections\/intrinsically-safe-2.oembed","provider":"R.C. Worst \u0026 Company Inc","version":"1.0","type":"link"}