{"title":"Capacitor Start\/Run","description":"","products":[{"product_id":"zoeller-10-0397-model-e840-or-i840-shark-control-panel-auto-reversing-circuit-duplex","title":"Zoeller 10-0397 Model E840 or I840 \"Shark\" Control Panel Auto Reversing Circuit Duplex","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\n\u003ch3\u003eZoeller Control Panel 840 Duplex Description\u003c\/h3\u003e\n\u003cp\u003e\n    The control panel can be housed in a NEMA 4X enclosure and be of a simplex  design which controls a single pump from a 3-float system or a duplex design which controls two pumps in an alternating lead\/lag cycle sequence from a 3 or 4-float system. The panel contains the required starting, control, \u0026amp; alarm circuits. Rated motor starters and circuit breakers are required for each pump. The 115 volt control circuit will have short circuit protection. The panel will have pump run pilot light(s) and pump \u0026amp; alarm selector switches. The panel will be equipped with circuit(s) which automatically reverses the direction of the cutter blades. A seal leak indicator light is required as well as a thermal cut-out connection for 3 phase systems. A padlock hasp will be provided. High water conditions will be indicated by a visible light with polycarbonate cover. Numbered terminal strips are required. A wiring schematic and trouble shooting guide will be included with each panel. The panel will be UL listed and be labeled as such.\n\u003c\/p\u003e\n\u003cp\u003e\n    Zoeller Control Panel w\/Automatic Reversing Circuit Std. Duplex. (840 only) 10-0397 fits:\n\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/p\/4656-Zoeller-840-0004-Model-E840-Shark-Auto-Reversing-Grinder-Pump-2-0-HP-230V-1PH-20-Cord-Automatic.html\" target=\"_blank\" title=\"Zoeller 840-0004 Model E840 \u0026quot;Shark\u0026quot; Auto Reversing Grinder Pump 2 HP 230V 1PH 20' Cord Automatic\"\u003eZoeller 840-0004 Model E840 \"Shark\" Auto Reversing Grinder Pump 2 HP 230V 1PH 20' Cord Automatic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/p\/4993-Zoeller-840-0005-Model-I840-Shark-Auto-Reversing-Grinder-Pump-2-0-HP-200V-1PH-20-Cord-Automatic.html\" target=\"_blank\" title=\"Zoeller 840-0005 Model I840 \u0026quot;Shark\u0026quot; Auto Reversing Grinder Pump 2 HP 200V 1PH 20' Cord Automatic\"\u003eZoeller 840-0005 Model I840 \"Shark\" Auto Reversing  Grinder Pump 2 HP 200V 1PH 20' Cord Automatic\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eZoeller Control Panel 840 Duplex Features and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA 4X Outdoor Rating\u003c\/li\u003e\n\u003cli\u003eStarting, Control, and Alarm Circuits\u003c\/li\u003e\n\u003cli\u003eThermal Cut-Out Circuit (3 phase only)\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker and Rated Motor Contactor (single phase)\u003c\/li\u003e\n\u003cli\u003eCapacitors and Motor Starting Relay On\u003c\/li\u003e\n\u003cli\u003eSingle Phase\u003c\/li\u003e\n\u003cli\u003eMotor Protective Switch (circuit breaker \/ adj overloads) and Rated Motor Contactor (3 Phase)\u003c\/li\u003e\n\u003cli\u003eAlternating Circuit (duplex)\u003c\/li\u003e\n\u003cli\u003eAutomatic Reversing Circuit\u003c\/li\u003e\n\u003cli\u003eHigh Water Alarm Light\u003c\/li\u003e\n\u003cli\u003eInternal Seal Leak Light\u003c\/li\u003e\n\u003cli\u003eHOA Switches and Pilot light(s)\u003c\/li\u003e\n\u003cli\u003eTerminal Strips\u003c\/li\u003e\n\u003cli\u003ePadlock Hasp\u003c\/li\u003e\n\u003cli\u003eCapacitors\/Start Relay (single phase)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323196612925,"sku":"ZLR10-0397","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_cc4e395c-af72-46f7-beb1-9ba71c3c6cd9.jpg?v=1725383433"},{"product_id":"zoeller-10-1652-model-841-842-duplex-control-panel-single-directional-200-230v-1ph","title":"Zoeller 10-1652 Model 841 \u0026 842 Duplex Control Panel Single Directional 200\/230V 1PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\n\u003ch3\u003eZoeller Duplex Control Panel Description\u003c\/h3\u003e\n\u003cp\u003e\nThe control panel can be housed in a NEMA 4X enclosure and be of a duplex\ndesign which controls two pumps in an alternating lead\/lag cycle sequence\nfrom a 3 or 4-float system. For Models 841 \u0026amp; 842, Single Directional\nonly. The panel contains the required starting, control, \u0026amp; alarm\ncircuits. Rated motor starters and circuit breakers are required for each\npump. The 115 volt control circuit will have short circuit protection. The panel will have pump run pilot light(s) and pump \u0026amp; alarm selector\nswitches. The panel will be equipped with circuit(s) which automatically\nreverses the direction of the cutter blades. A seal leak indicator light is\nrequired as well as a thermal cut-out connection for 3 phase systems. A\npadlock hasp will be provided. High water conditions will be indicated by a\nvisible light with polycarbonate cover. Numbered terminal strips are\nrequired. A wiring schematic and trouble shooting guide will be included\nwith each panel. The panel will be UL listed and be labeled as such.\u003c\/p\u003e\n\u003ch3\u003eZoeller Duplex Control Panel Features and Benefits\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003eHand Off Auto Toggle Switch for Each Pump\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\u003c\/li\u003e\n\u003cli\u003eAlarm Test and Silence Switches\u003c\/li\u003e\n\u003cli\u003eRed Pilot Light (NEMA 1 only) and Audible Alarm with 83 to 85 Decibel Rating for a High Water Condition\u003c\/li\u003e\n\u003cli\u003eRed Alarm Beacon Included with NEMA 4X Enclosure\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\u003c\/li\u003e\n\u003cli\u003eHigh Water Alarm\u003c\/li\u003e\n\u003cli\u003eOn Single Phase – Circuit Breaker for Each Pump\u003c\/li\u003e\n\u003cli\u003eMagnetic Starter for Each Pump\u003c\/li\u003e\n\u003cli\u003eAlternating Mechanism\u003c\/li\u003e\n\u003cli\u003eNumbered Terminal Strip for Connecting Pumps and Variable Level Float Switches\u003c\/li\u003e\n\u003cli\u003eNEMA 1, General Purpose or NEMA 4X, Watertight Enclosures Available\u003c\/li\u003e\n\u003cli\u003eIntegral Auxiliary Terminal Board Connections (dry contact) for Remote Alarm Devices\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Level Float Switch Control Operation\u003c\/li\u003e\n\u003cli\u003eThree 20’ Float Switches Included With Single Phase Panels\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy Field Maintenance and Repair\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323200708925,"sku":"ZLR10-1652","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0393_w_a25c383f-7c98-4809-bafa-fb5d4ec55ed0.jpg?v=1725383500"},{"product_id":"zoeller-10-2713-intrinsically-safe-control-panel-duplex-auto-200-230v-1ph","title":"Zoeller 10-2713 Intrinsically Safe Control Panel Duplex Auto 200\/230V 1PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2713 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5010-Zoeller-840-0064-Model-EX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-230V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 840-0064 Model EX840 \u0026quot;Shark\u0026quot; Reversing Grinder Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\"\u003eZoeller 840-0064 Model EX840 \"Shark\" Reversing Grinder        Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5011-Zoeller-840-0065-Model-IX840-Shark-Reversing-Grinder-Pump-Explosion-Proof-2-0-HP-200V-1PH-20-Cord-Nonautomatic.html\"\u003eZoeller 840-0065 Model IX840 \"Shark\" Reversing Grinder Pump Explosion        Proof 2 HP 200V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn with Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eThermal Cutouts for 3 Phase\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323207328061,"sku":"ZLR10-2713","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_abfd1557-33a5-4d35-9ee2-27ac682397a5.jpg?v=1725383557"},{"product_id":"zoeller-10-2721-intrinsically-safe-control-panel-duplex-single-direction-200-230v-1ph","title":"Zoeller 10-2721 Intrinsically Safe Control Panel Duplex Single Direction 200\/230V 1PH","description":"\u003ch3\u003e\n\u003cimg alt=\"zoeller-logo.jpg\" data-sz=\"f\" height=\"93\" id=\"mNkjyVLY-JcQXM:\" name=\"mNkjyVLY-JcQXM:\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/zoeller-logo.jpg\" width=\"299\"\u003e\n\u003c\/h3\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Description\n\u003c\/h3\u003e\u003cp\u003e\n    These intrinsically safe control panels are used on pump applications\n    defined as hazardous duty locations. Lift stations in some regions fall\n    under this classification. The intrinsically safe panel, in conjunction\n    with an explosion proof pump, will provide a system that will not allow\n    ignition of the explosive gases. The purpose of the control panel is to\n    cycle a pump automatically. Each panel comes standard with pump run\n    light(s), a high water audible and visual alarm, seal fail indicator(s),\n    and a UL Listing. All panels come standard with a NEMA 4X rating for indoor\n    or outdoor use.\u003c\/p\u003e\u003cp\u003e\n    These panels MUST NOT be in the space classified as needing explosion proof\n    equipment. Special fittings that either prevent the passage of hot gases,\n    in the case of an explosion in a Class 1 area or the passage of a\n    combustible dust, fibers or flyings in a Class 2 or 3 area (NEC 501-5 and\n    502-5), are required. A qualified electrician must install all electrical\n    systems. National Electrical Code (NEC) articles 500 through 503 explain in\n    detail the requirements for the installation of wiring or electrical\n    equipment in hazardous locations. These articles along with any other\n    applicable regulations, local governing inspection authorities, insurance\n    representatives and qualified engineering\/technical assistance should be\n    your guides to the installation of wiring or electrical equipment in any\n    hazardous or potentially hazardous locations\u003c\/p\u003e\u003cp\u003e\n    Zoeller Intrinsically Safe Control Panel 10-2721 fits Model(s):\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5016-Zoeller-841-0017-Model-EX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-230V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 841-0017 Model EX841 \u0026quot;Shark\u0026quot; High Flow Grinder Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\"\u003eZoeller 841-0017 Model EX841 \"Shark\" High Flow Grinder        Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5022-Zoeller-842-0011-Model-EX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-230V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 842-0011 Model EX842 \u0026quot;Shark\u0026quot; High Head Grinder Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\"\u003eZoeller 842-0011 Model EX842 \"Shark\" High Head Grinder Pump Explosion Proof 2 HP 230V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5017-Zoeller-841-0018-Model-IX841-Shark-High-Flow-Grinder-Pump-Explosion-Proof-2-0-HP-200V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 841-0018 Model IX841 \u0026quot;Shark\u0026quot; High Flow Grinder Pump Explosion Proof 2 HP 200V 1PH 20' Cord Nonautomatic\"\u003eZoeller 841-0018 Model IX841 \"Shark\" High Flow Grinder Pump Explosion Proof 2 HP 200V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/p\/5023-Zoeller-842-0012-Model-IX842-Shark-High-Head-Grinder-Pump-Explosion-Proof-2-0-HP-200V-1PH-20-Cord-Nonautomatic.html\" target=\"_blank\" title=\"Zoeller 842-0012 Model IX842 \u0026quot;Shark\u0026quot; High Head Grinder Pump Explosion Proof 2 HP 200V 1PH 20' Cord Nonautomatic\"\u003eZoeller 842-0012 Model IX842 \"Shark\" High Head Grinder        Pump Explosion Proof 2 HP 200V 1PH 20' Cord Nonautomatic\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\nZoeller Intrinsically Safe Control Panel Features and Benefits\n\u003c\/h3\u003e\u003cdiv class=\"c2\"\u003e\n\u003cul\u003e\n\u003cli\u003eIntrinsically Safe Relays\n\t\t\u003c\/li\u003e\n\u003cli\u003eNEMA 4X Enclosure\n\t\t\u003c\/li\u003e\n\u003cli\u003eTop Mounted Alarm Light\n\t\t\u003c\/li\u003e\n\u003cli\u003eHands-Off-Auto Toggle Switch for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eUL Listed\n\t\t\u003c\/li\u003e\n\u003cli\u003eAlarm Horn With Silence Switch\n\t\t\u003c\/li\u003e\n\u003cli\u003eMagnetic Motor Contractor\n\t\t\u003c\/li\u003e\n\u003cli\u003eLockable Latch\n\t\t\u003c\/li\u003e\n\u003cli\u003eAuxiliary Dry Contact\/High Water Alarm\n\t\t\u003c\/li\u003e\n\u003cli\u003eCircuit Breaker Pump Disconnect\n\t\t\u003c\/li\u003e\n\u003cli\u003e3 or 4 Variable Float Switch Control Operation\n\t\t\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\n\t\t\u003c\/li\u003e\n\u003cli\u003eThe Use of Off-the-Shelf Components Provide for Relatively Easy\n        Field Maintenance and Repair\n\t\t\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Pilot Light for Each Pump\n\t\t\u003c\/li\u003e\n\u003cli\u003eSeal Fail Indicator Light(s)\n\t\t\u003c\/li\u003e\n\u003cli\u003eDuplex Only – Lead\/Lag Alternating Circuit\n\t\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Zoeller","offers":[{"title":"Default Title","offer_id":49323211751741,"sku":"ZLR10-2721","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/10_0125_w_1b884d78-52eb-4f27-8404-f5c765828258.jpg?v=1725383612"},{"product_id":"sje-rhombus-model-ifs8-single-phase-120-208-240v-capacitor-start-run-duplex-control-panel","title":"SJE-Rhombus Model IFS8 Single Phase 120\/208\/240V Capacitor Start\/Run Duplex Control Panel","description":"\u003cp\u003e\u003cimg alt=\"sjerhombuslogo6002018.jpg\" data-image=\"4vd839fpfwa6\" height=\"97\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/sjerhombuslogo6002018.jpg\" title=\"sjerhombuslogo6002018.jpg\" width=\"600\"\u003e\u003c\/p\u003e\n\u003ch3\u003eSJE-Rhombus Model IFS Single Phase Duplex Capacitor (Start\/Run) Panel Description\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSingle Phase, Duplex Demand Dose, Float or C-Level™ Controlled System for Pump Control and System Monitoring.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IFS single phase duplex capacitoru (start\/run) control panel is designed to alternately control two 120\/208\/240 VAC single phase pump in water and sewage applications. The IFS single phase simplex capacitor (start\/run) control panel features an easy-to-use color LCD interface located on the inner door for programming and system monitoring. The panel configuration can be easily converted in the field to either a timed dose or demand dose through the LCD interface.\u003c\/p\u003e\n\u003cp\u003eThe panel can easily be changed in the field to utilize floats, Sub-X™ LT Transmitter or the C-Level™ Sensor for continuous monitoring. The Sub-X™ LT Transmitter and the C-Level™ Sensor sense the level in the tank and sends a signal to the panel. Pump activation levels can be adjusted by using the LCD interface.\u003c\/p\u003e\n\u003ch3\u003eSJE-Rhombus Model IFS Single Phase Duplex Capacitor (Start\/Run) Panel Features\u003c\/h3\u003e\n\u003cp\u003e\u003cu\u003e\u003cstrong\u003eLCD Interface Features:\u003c\/strong\u003e\u003c\/u\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFull Color Graphics and Menu Navigation Encoder for Easy Setup\u003c\/li\u003e\n\u003cli\u003eTouch Safe Housing\u003c\/li\u003e\n\u003cli\u003ePump Hand\/Off\/Auto Control Selectable via Menu Navigation\u003c\/li\u003e\n\u003cli\u003eSub-X™ LT Transmitter, C-Level™ Sensor or Float Operation Selectable\u003c\/li\u003e\n\u003cli\u003eDemand or Timed Dose Operation Selectable via Menu Navigation\u003c\/li\u003e\n\u003cli\u003eTank Level Indication and Setpoint Monitoring At-A-Glance\u003c\/li\u003e\n\u003cli\u003eLead Pump is Easily Identified by a Graphic Ring Around the Current Lead Pump Regardless of Control Mode (timed dose or demand)\u003c\/li\u003e\n\u003cli\u003eDisplays Remaining Time in Timed Dose Mode\u003c\/li\u003e\n\u003cli\u003eRJ45 Communication Connector\u003c\/li\u003e\n\u003cli\u003eFlashing Function for Alarm Beacon and Horn (configurable)\u003c\/li\u003e\n\u003cli\u003eManual Alarm Reset (configurable)\u003c\/li\u003e\n\u003cli\u003eThermal Cutout and Seal Failure Module (optional)\u003c\/li\u003e\n\u003cli\u003eUL\/cUL Listed\u003c\/li\u003e\n\u003cli\u003eWarranty\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eFive-Year Limited Warranty on Panel. This Express Warranty does not Apply to the Motor Start Kit Components. SJE Rhombus will Warranty Motor Start Kit Components Supplied by SJE Rhombus for One Year. SJE Rhombus Makes no Warranties of any Type with Respect to Motor Start Kits Supplied by a Customer\u003c\/li\u003e\n\u003cli\u003eTwo-Year Limited Warranty on C-Level™ Sensor and Sub-X™ LT Transmitter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"SJE Rhombus","offers":[{"title":"Default Title","offer_id":49327782461757,"sku":"CP-SJEIFS8","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/sjeifs8panel23_001_wbg.jpg?v=1774557835"},{"product_id":"sje-rhombus-model-123-duplex-single-phase-duplex-capacitor-start-run-pump-control-w-override","title":"SJE-Rhombus Model 123 Duplex Single Phase Duplex Capacitor Start\/Run Pump Control w\/Override","description":"\u003cp\u003e\n\u003cimg alt=\"sjerhombuslogo6002018.jpg\" data-image=\"pbzhsdfi7hm7\" height=\"97\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/sjerhombuslogo6002018.jpg\" title=\"sjerhombuslogo6002018.jpg\" width=\"600\"\u003e\n\u003c\/p\u003e\n\u003ch3\u003eSJE-Rhombus Model 123 - Single Phase Duplex Capacitor Control Panel Description\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSingle Phase, Duplex Capacitor Start\/Run Pump Control with Override\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e The Model 123 Control Panel is designed to control two 120,208 or 240 VAC single phase pumps requiring external starting components in water and sewage installations. The controller is provided with a pump selector switch that can be set to alternate the pumps to equalize wear or to call either pump to active first with the other pump to activate in lag condition. If an alarm occurs, the alarm activates the audible-visual system. The alarm conditions include: high water, float-out-of-sequence, pump fail-to-run, seal failure (optional). Common applications include pump chambers and lift stations.\u003c\/p\u003e\n\u003ch3\u003eSJE-Rhombus Model 123 - Single Phase Duplex Capacitor Control Panel Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cu\u003e\u003cstrong\u003ePanel Features:\u003c\/strong\u003e\u003c\/u\u003e\n\u003cli\u003eNEMA 4X (indoor\/outdoor) Enclosure\u003c\/li\u003e\n\u003cli\u003eRed Alarm Beacon Provides 360º Visual Check of Alarm Condition\u003c\/li\u003e\n\u003cli\u003eAlarm Horn Provides Audio Warning of Alarm Condition\u003c\/li\u003e\n\u003cli\u003eExterior Alarm Test\/Normal\/Silence Switch Allows Horn and Light to be Tested and Horn to be Silenced in an Alarm Condition; Alarm Automatically Resets Once Alarm Condition is Cleared\u003c\/li\u003e\n\u003cli\u003eHorn Silence Relay\u003c\/li\u003e\n\u003cli\u003eIEC Motor Contactor Controls Pump by Switching Electrical Lines\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Auto (HOA) Switch for Manual Pump Control\u003c\/li\u003e\n\u003cli\u003eGreen Pump Run Indicator Light\u003c\/li\u003e\n\u003cli\u003eAlternating Circuit Board (U.S. patent # 5,909,352) Provides Pump Control and Alternation\u003c\/li\u003e\n\u003cli\u003eControl On\/Off Switch\u003c\/li\u003e\n\u003cli\u003eFloat Status Indicator Lights\u003c\/li\u003e\n\u003cli\u003eControl\/Alarm Power Indicator Light\u003c\/li\u003e\n\u003cli\u003eIncoming Pump Power Terminal Block\/Pump Terminal Block\u003c\/li\u003e\n\u003cli\u003eCircuit Breakers (optional) Provide Pump Disconnect and Branch Circuit Protection\u003c\/li\u003e\n\u003cli\u003eGround Lugs\u003c\/li\u003e\n\u003cli\u003eCapacitor Start Modules* \u003c\/li\u003e\n\u003cli\u003eUL\/cUL Listed\u003c\/li\u003e\n\u003cli\u003eFive-Year Limited Warranty\u003c\/li\u003e\n\u003cu\u003e\u003cb\u003e*Start\/Run Capacitor Kits Must Be Ordered Separately. Model 123 Control Panels Cannot be Returned\u003c\/b\u003e\u003c\/u\u003e\n\u003c\/ul\u003e","brand":"SJE Rhombus","offers":[{"title":"Default Title","offer_id":49327786361149,"sku":"CP-SJE123","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/files\/sjemodel123panel_001_wbg.jpg?v=1725457958"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0857\/5552\/7485\/collections\/10_0125_w_cce0b5c4-bb74-4c0d-994d-343d71b6f7ce.jpg?v=1727897801","url":"https:\/\/rcworst.com\/collections\/capacitor-start-run-2.oembed","provider":"R.C. Worst \u0026 Company Inc","version":"1.0","type":"link"}