This is where R.C. Worst & Company Inc. talks about stuff related to our industry!
Posted on Wednesday, October 18, 2017 by

How to Troubleshoot Franklin Electric Control Boxes (1.5 - 15 HP)

Standard and Deluxe boxes are for 1 hp - 15 hp single-phase water systems that use standard/heavy-duty pressure switches, level switches or other pilot devices. Deluxe boxes contain magnetic line contactors carefully matched to the motor rating, eliminating the need for external line contactors. The 15 hp XL Deluxe box has a larger enclosure that provides the space you need for heavy-duty wire and plenty of room for add-ons. I have outlined some troubleshooting steps below to help investigate...

Continue Reading
Posted on Friday, October 13, 2017 by

Troubleshooting Submersible Well Pumps 101: Testing a Franklin Electric QD (Quick Disconnect) Box

QD Boxes are designed for use with 3-wire, single phase submersible motors from ? to 1 hp. Troubleshooting inside the box is made simple by the control components automatically disconnecting from the system when the lid is removed. I have outlined some troubleshooting steps below to help investigate problems with your QD Control Box. Caution! Electricity can be very dangerous, especially if you are inexperienced. Always use caution working with electricity and turn off power supply breakers...

Continue Reading
Posted on Thursday, October 12, 2017 by

Troubleshooting Submersible Well Pumps 101: Overloads Tripping

Is your well water pump overload protector tripping in your control panel? I have outlined some troubleshooting steps below to help investigate the possible cause. Caution! Electricity can be very dangerous, especially if you are inexperienced. Always use caution working with electricity and turn off power supply breakers when testing components within the electrical system. If you are not 100% confident you can perform any of these tests safely, call a professional. Check the Voltage. Voltage...

Continue Reading
Posted on Thursday, October 12, 2017 by

Troubleshooting Submersible Well Pumps 101: Pump Will Not Start

Is your submersible well pump not starting? I have outlined some troubleshooting steps below to help investigate the possible cause. Caution! Electricity can be very dangerous, especially if you are inexperienced. Always use caution working with electricity and turn off power supply breakers when testing components within the electrical system. If you are not 100% confident you can perform any of these tests safely, call a professional. 1. Check for blown fuses and tripped breakers. 2. Check...

Continue Reading
Posted on Wednesday, October 4, 2017 by

Troubleshooting Submersisble Well Pumps 101: Pump Won't Shut Off / Low Water Pressure

Is your submersible well pump not shutting off? Has the system operating pressure dropped in your submersible well pump system? If you answered yes to either of these questions it is important to do some troubleshooting before your well pump wears out or you burn out the motor. I have outlined some steps to follow below. Caution! Electricity can be very dangerous, especially if you are inexperienced. Always use caution working with electricity and turn off power supply breakers when testing...

Continue Reading