Prev Next

Myers MSB3SD300M4-4 Submersible Sewage Pump 3 HP 460V 3PH Manual 1750 RPM 35' Cord

Price: $5,720.00
Quantity:
+ -
Usually ships within 2 weeks
SKU: MYR28222E114


Shipping Weight:
180.0 LBS
Shipping Dimensions
Length: 24 In
Width: 24 In
Height: 29 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Myers MSB3SD Sumbersible Sewage Pump Description

The Myers MS3SD/MSB3SD Sumbersible Sewage Pumps are suited for wet-well installation in a wide variety of municipal, industrial and building trades applications. Sewage Pumps are necessary to move sewage from a building to the sewer system and in many cases from the sewer sytem to the treatment plant.

Myers MSB3SD Sumbersible Sewage Pump Typical Application

  • Municipal Sewage Lift Stations
  • Industrial Sewage Transfer
  • Dewatering of Storm Water

Myers MSB3SD Sumbersible Sewage Pump Features

  • Motor Fully Enclosed Oil-Filled Motor Efficiently Dissipates Heat and Locks Out Moisture so you Receive Reliable Pumping Service.
  • CPE Jacketed Power Cord Sealed by Both the Cord Grip and the Epoxy Barrier.
  • Stainless Steel Shaft Eliminates Corrosion and Fatigue to Give Longer Pump Life. The Minimum Shaft Overhang Decreases Deflection and Increases Bearing and Seal Life.
  • Ball Bearings the Heavy Duty Ball Bearings, Upper (radial) and Lower (thrust), are Submerged in Oil to Provide Permanent Lubrication and Ensure Long Service Life.
  • Mechanical Seal Constructed with a Ceramic Stationary Face and Carbon Rotating Face for Long Service Life.
  • Impeller Two-Vane, Semi-Open Design for Efficient Operation without Clogging. The Impeller has Pump-Out Vanes to Prevent Material Buildup Around Shaft and Seal.
  • Vertical Discharge Model MSB3SD Handles 2-1/2" Spherical Solids and has a Flanged 3" Vertical Discharge.
  • Sensor Probe A Seal-Failure Sensor Probe (for connection to a seal failure alarm) is Standard on Three-Phase Units and Available as an Option on Single Phase Models.

Myers MSB3SD300M4-4 Sumbersible Sewage Pump Technical Details

  • VOLTAGE: 3ø, 460V, 60Hz
  • HORSEPOWER: 3.0 HP
  • AMP DRAW (full load): 4.8
  • MOTOR TYPE: Enclosed, Oil Cooled Induction
  • RPM: 1750
  • MAXIMUM HEAD: up to 35'
  • MAXIMUM CAPACITY: up to 385 GPM
  • SWITCH TYPE: Manual
  • MINIMUM SUMP DIAMETER: Simplex 30"
  • DISCHARGE PIPE SIZE: 3.0" Flanged Vertical
  • MAXIMUM SOLIDS HANDLING SIZE: 2-1/2"
  • IMPELLER TYPE: Ductile Iron, Non-Clogging, Two-Vane, Semi-Open 
  • IMPELLER DIAMETER: Varies
  • CORD LENGTH: 35' 
  • CORD SIZE: 14-4; Type: SOOW, W
  • BODY CONSTRUCTION: Class 30 Cast Iron; ASTM A-48
  • MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)
  • CONTROL BOX REQUIRED

Myers MSB3SD Sumbersible Sewage Pump Curve

ms3sd-msb3sd-1150-2-curve.jpg


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned