Prev Next

Myers MES100M2 20 Submersible Effluent Pump 1.0 HP 230V 1PH Manual 20' Cord

Price: Discontinued
+ -
Discontinued or no longer available.
SKU: MYR28216D102


Shipping Weight:
65.0 LBS
Shipping Dimensions
Length: 14 In
Width: 12 In
Height: 24 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Discontinued

Myers MES100 Submersible Effluent Pump Description

The MES Series are completely submersible "high head" pumps for use in residential septic tank effluent pumping applications and are available in automatic and manual configuration. Automatic models feature a wide-range float switch with piggyback plug-in arrangements. Switch is adjustable, easy to service and allows for simple conversion to manual operations.

Myers MES100 Submersible Effluent Pump Typical Application

  • High Quality Cast Iron Construction of Pump Volute, Motor Housing and Seal Housing Provides Long Life.
  • Water Resistant Power Cord has a Compression Fit Connection and an Epoxy Potting for Double Protection Against Water Entry.
  • Oil-Filled Motor Provides Superior Cooling and Permanent Lubrication of Bearings, Minimizing Maintenance and Extending Service Life.
  • Upper Radial- and Lower Thrust Bearings are Heavy-Duty, Single-Row Ball Bearings that are Permanently Lubricated for Service-Free Life.
  • 1/2 and 1 HP Capacitor-Start (1ø) Motors Provide Maximum Starting Torque. Motor windings Contain Automatic Thermal Overload Protection (1ø).
  • Mechanical Shaft Seal is Carbon and Ceramic-Faced for Long Leakproof Life.
  • Discharge is Standard 2” NPT
  • 2” High Corrosion-Resistant Legs Raise Pump’s Inlet from Bottom of Septic Tank Pump Chamber
  • Corrosion-Resistant, Nonclog Base with Strainer-Free Inlet Capable of Passing Two (2), 3/4” Diameter Spherical Solids Simultaneously.
  • High Corrosion-Resistant, Nonclog Impeller Passes Two (2), 3/4” Spherical Solids.

Myers MES100M2 Submersible Effluent Pump Technical Details

  • VOLTAGE: 1ø, 230V, 60 Hz
  • HORSEPOWER: 1.0HP
  • AMP DRAW (full load): 13.6
  • MOTOR TYPE: Capacitor Start
  • RPM: 3450
  • MAXIMUM HEAD: 90'
  • MAXIMUM CAPACITY: 87 GPM
  • SWITCH TYPE: Manual
  • DISCHARGE PIPE SIZE: 2.0" NPT
  • MAXIMUM SOLIDS HANDLING: 3/4"
  • IMPELLER TYPE: Engineered Thermoplastic, Recessed Vortex
  • CORD LENGTH: 20' 
  • CORD SIZE: 16-3 Type; SJTW
  • BODY CONSTRUCTION: Cast Iron
  • MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)

Myers MES50 & MES100 Submersible Effluent Pump Curve

Myers MES50 and MES100 Pump Curve


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned