Hydromatic S3HX Hazardous Submersible Solids Handling Pumps Description

Hydromatic S3HX Hazardous Submersible Solids Handling Pumps is designed to meet the demands of Municipal, Commercial and Industrial Areas.

Hydromatic S3HX Typical Application

  • Municipal
  • Commercial
  • Industrial
  • Hazardous Locations Class I, Division I

Hydromatic S3HX Superior Features

  • Oil filled motor efficiently dissipates heat and locks out damaging moisture so you receive reliable pumping service. Easily field serviceable.
  • Standard construction is cast iron.
  • Stainless steel shaft eliminates corrosion and fatigue for longer pump life. The minimum shaft overhang decreases bearing and seal life. Tapered shaft allows for easy removal of impeller.
  • Available with a wide range of impellers for different applications. Pump-out vanes on the top shroud prevent the buildup of materials in the seal area and extend the life of the thrust bearing by significantly reducing axial thrust.
  • The connection box has two epoxy barriers and a compression fitting that prevent water contamination of the motor area, assuring long-term reliable operation. In addition, epoxy encapsulation and stripped leads positively eliminate "wicking" from the cable
  • Heavy duty upper and lower ball bearings are submerged in oil to provide permanent lubrication and ensure long service life.
  • Easily replaceable, true wear ring, with a top pullout design for easy disassemble operation.
  • Flame-proof joints have 1-¼" flame paths. These close tolerance joints prevent any internal spark or fire from escaping into the environment.
  • The hazardous location housing wall is thicker throughout the case to give you extra containment capability.
  • Two moisture sensors in the oil chamber provide extra security. The sensors are electrically isolated and made with stainless steel connections and stainless steel probes and heavy-duty bearings for long pump life.
  • The special Labyrinth joint gives you added protection by preventing flame or spark travel to the media being pumped

Hydromatic S3HX100CB Technical Details

  • BODY CONSTRUCTION: Class 30 Cast Iron
  • HORSEPOWER: 1.0 HP
  • RPM: 1150
  • MAXIMUM HEAD: up to 13'
  • MAXIMUM CAPACITY: up to 230 GPM
  • DISCHARGE PIPE SIZE: 3" Vertical Discharge
  • MAXIMUM SOLIDS HANDLING SIZE: 2.5"
  • CORD LENGTH: 35' Standard
  • OPTIONAL CORD LENGTH: 50'
  • CORD SIZE: 14-4; Type: SOOW/W
  • AMP DRAW (full load): 8.2
  • VOLTAGE: 1ø, 230V
  • MAXIMUM LIQUID TEMPERATURE: 140°F
  • MOTOR: Enclosed, Oil Cooled Induction, VFD Suitable
  • IMPELLER CONSTRUCTION: Balanced, Enclosed, 2 Vane, Ductile Iron, ASTM A536
  • IMPELLER SIZE: 6.63"
  • Section 300

Hydromatic S3HX Pump Curve


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

STANDARD LIMITED WARRANTY Pentair Hydromatic® warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Pentair Hydromatic or 18 months from the manufacturing date, whichever occurs first – provided that such products are used in compliance with the requirements of the Pentair Hydromatic catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids.

During the warranty period and subject to the conditions set forth, Pentair Hydromatic, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Hydromatic reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units.

Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start up through the Pentair Hydromatic website: http://forms.pentairliterature.com/startupform/startupform.asp?type=h. Warranty is effective only if Pentair Hydromatic authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Hydromatic will cover only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Hydromatic be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Hydromatic service facility.

This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Hydromatic or an authorized Pentair Hydromatic service provider; (h) to any unit that has been repaired using non factory specified/ OEM parts.

Warranty Exclusions: Pentair HYDROMATIC MAKES NO EXPRESS OR IMPLIED WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. Pentair HYDROMATIC SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.

Liability Limitation: IN NO EVENT SHALL Pentair HYDROMATIC BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY Pentair HYDROMATIC PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION. Pentair HYDROMATIC DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR IMPROPER INSTALLATION. Pentair HYDROMATIC RECOMMENDS INSTALLATION BY PROFESSIONALS.

Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or consequential damages and therefore such limitations may not apply to you. No warranties or representations at any time made by any representatives of Pentair Hydromatic shall vary or expand the provision hereof.

We've been helping customers since 1953

Trust Guard Security Scanned