Hydromatic HPGH Submersible Sewage Grinder Pump Description

Hydromatic HPGH Submersible Sewage Grinder Pump is designed to meet the demands of Residential, Commercial and Resort Areas.

Hydromatic HPGH Typical Application

  • Residential
  • Commercial
  • Resort Area

Hydromatic HPGH Superior Features

  • One epoxy barrier and one compression fitting for maximum protection against wicking and water seepage into the motor housing.
  • The heavy-duty ball bearings, upper (radial) and lower (thrust), are continuously lubricated by oil to ensure long service life.
  • Electrical motor design combines the advantages of high torque output with optimum running efficiency engineered specifically for grinder operation.
  • The stator is secured to the motor housing by means of stator bolts and retaining ring which ensure ease of maintenance if the need ever arises.
  • Standard stainless steel shaft in grinder pump
  • Dual seals for maximum moisture protection.
  • Moisture detection probe.
  • Exclusive “Dual Cutter” design cuts solids to smallest particle size, thereby greatly reducing clogging, roping, or binding.
  • Standard impeller provides highest level of corrosion resistance and maximum toughness from impact for a wide variety of slurry pumpage. Pump-out vanes preclude material buildup around shaft and seal.

Hydromatic HPGH Key Features

  • Explosion-proof
  • Class 1, Division 1, Groups C & D
  • Dual seals for maximum moisture protection
  • Oil-filled motor for maximum heat dissipation and constant bearing lubrication
  • Exclusive dual cutter design cuts solids to the smallest particle size
  • Semi-open impeller provides steep non-overloading operating curve
  • Available configurations, rails and accessories:
    • Rail Systems Available
    • Controls and Accessories Available

Hydromatic HPGH500M7-2 Technical Details

  • BODY CONSTRUCTION: Class 30 Cast Iron
  • HORSEPOWER: 5.0 HP
  • RPM: 3450
  • MAXIMUM HEAD: up to 155'
  • MAXIMUM CAPACITY: up to 115 GPM
  • DISCHARGE PIPE SIZE: 2" NPT Discharge
  • CORD LENGTH: 35' Standard
  • CORD SIZE: 8-4; Type: SOOW, W
  • AMP DRAW (full load): 33.9
  • VOLTAGE: 1ø, 200V
  • MAXIMUM LIQUID TEMPERATURE: 140°F
  • MOTOR: Enclosed, Oil Cooled Induction
  • IMPELLER CONSTRUCTION: Semi-Open 5 Vane, Red Brass #85-5-5-5, ASTM B584-836
  • IMPELLER SIZE: 6.25"

Hydromatic HPGH Pump Curve


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

STANDARD LIMITED WARRANTY Pentair Hydromatic® warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Pentair Hydromatic or 18 months from the manufacturing date, whichever occurs first – provided that such products are used in compliance with the requirements of the Pentair Hydromatic catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids.

During the warranty period and subject to the conditions set forth, Pentair Hydromatic, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Hydromatic reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units.

Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start up through the Pentair Hydromatic website: http://forms.pentairliterature.com/startupform/startupform.asp?type=h. Warranty is effective only if Pentair Hydromatic authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Hydromatic will cover only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Hydromatic be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Hydromatic service facility.

This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Hydromatic or an authorized Pentair Hydromatic service provider; (h) to any unit that has been repaired using non factory specified/ OEM parts.

Warranty Exclusions: Pentair HYDROMATIC MAKES NO EXPRESS OR IMPLIED WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. Pentair HYDROMATIC SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.

Liability Limitation: IN NO EVENT SHALL Pentair HYDROMATIC BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY Pentair HYDROMATIC PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION. Pentair HYDROMATIC DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR IMPROPER INSTALLATION. Pentair HYDROMATIC RECOMMENDS INSTALLATION BY PROFESSIONALS.

Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or consequential damages and therefore such limitations may not apply to you. No warranties or representations at any time made by any representatives of Pentair Hydromatic shall vary or expand the provision hereof.

We've been helping customers since 1953

Trust Guard Security Scanned