Prev Next

Myers ME3F-11-01 Cast Iron Effluent Pump 0.33 HP 115V 20' Cord Manual

Price: $435.33
Quantity:
+ -
Usually ships within 2 weeks
SKU: MYRME3F11


Shipping Weight:
39.0 LBS
Shipping Dimensions
Length: 20 In
Width: 16 In
Height: 16 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Myers ME3 Series Cast Iron Effluent Pump Description

The Myers ME3 Series Submersible Effluent Pumps are constructed of the most durable combination of materials to withstand the harshest environments. The ME3 Myers sump pump is available with a recessed impeller for high-head applications or an enclosed impeller for high-flow installations. Available in tethered automatic piggyback models or manual models for use with external controls.

Myers ME3 Series Cast Iron Effluent Pump Typical Applications

  • Effluent Removal
  • Sump Drainage
  • Water Transfer
  • Flood Control

Myers ME3 Series Cast Iron Effluent Pump Features

  • Maximum Heat-Handling: Durable, Oil-Filled Motor for Continuous Bearing Lubrication and Maximum Heat Dissipation
  • Powerful Starts: High-Torque, No Starting Switches or Relays to Wear Out
  • Thermal Protection: Heat Sensor Overload Protection with Automatic Reset when Motor Cools to a Safe Operating Temperature
  • Long-Lasting Motor: Lower Ball Bearing Eliminates Sleeve Bearing Wear and Reduces Motor Wear
  • Manual Operation: Tethered Automatic Models can be Operated Manually by Unplugging Piggyback Switch and Plugging Pump Directly into Outlet

Myers ME3F-11-01 Cast Iron Effluent Pump Specifications

  • VOLTAGE: 1ø, 115V, 60 Hz
  • HORSEPOWER: 0.33 HP
  • AMP DRAW (full load): 12.0
  • MOTOR TYPE: Oil-Filled Shaded Pole w/ Built-In Thermal Overload Protection
  • RPM: 1550
  • MAXIMUM HEAD: 32'
  • MAXIMUM CAPACITY: 66 GPM
  • SWITCH TYPE: Manual
  • MINIMUM SUMP DIAMETER: Simplex 24" Duplex 36"
  • DISCHARGE PIPE SIZE: 1-1/2" NPT
  • MAXIMUM SOLIDS HANDLING SIZE: 3/4"
  • IMPELLER TYPE: Engineered Thermoplastic, Two-Vane Enclosed
  • CORD LENGTH: 20'
  • CORD SIZE: 16/3; Type: SJTW
  • BODY CONSTRUCTION: Cast Iron
  • MAXIMUM LIQUID TEMPERATURE: 140°F (60C)

Myers ME3 Series Cast Iron Effluent Pump Performance Data


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned